Z-purlin and girt design calculator

ColdCalc designs continuous Z and C purlins and girts to AISI S100-24. It analyses the lapped member on a sloped roof with bending about both axes and warping torsion, then checks bending, shear, web crippling, bending with torsion, and wind uplift with the R factor of Section I6.2.1 at every support, lap end, brace and moment peak.

Start free trialOpen this example7 days free, then $29.99 a month. Card required; cancel before the first charge and pay nothing. Already have a plan? Open this example goes straight to the calculator.

What you get

This is the result for the design the calculator opens on, computed by the ColdCalc engine when this page was built. Change any input in the calculator and it reruns in about a second.

CheckS100-24Ratio
Bending, strong axis
27.00 ft, 1.2D + S
§F2.2, §F3.2, §F40.97NEAR
Shear
23.00 ft, 1.2D + S
§G2.10.15OK
Shear along the flanges
23.00 ft, 1.2D + S
§G2.10.04OK
Web crippling
0.00 ft, 1.2D + S
§G5, EOF0.39OK
Bending and shear combined
27.00 ft, 1.2D + S
§H2, Eq. H2-10.63OK
Bending and web crippling combined
25.00 ft, 1.2D + S
§H3, Eq. H3-3 (nested Z)0.47OK
Bending and torsion combined
27.00 ft, 1.2D + S
§H4, Eq. H4-1 (limit 1.25)0.97NEAR
Deflection
40.00 ft, D + 0.7S
Appendix 10.67OK

Z 8×2.5×0.085, Fy = 55 ksi, 2 spans of 25 ft and 25 ft, at 60 in. on center. AISI S100-24 LRFD, Direct Strength Method, finite strip buckling. A ratio is demand over available strength, or an interaction value over its limit; 1.00 or less passes.

What it checks

CheckWhat it coversAISI S100-24
BendingLateral-torsional, local and distortional buckling in the spans, at lap ends and over supports§F2, §F3, §F4
Uplift on through-fastened purlinsThe reduction factor R of Table I6.2.1-1 applied to the bending strength§I6.2.1
Bending and torsionThe bimoment from loads off the shear center, from a warping torsion analysis§H4, §G8
Shear, and bending with shearEach member of a lap carries its share by stiffness§G2, §H2
Web crippling, and with bendingAt rafters, including nested Z laps§G5, §H3
DeflectionService-load deflection of the continuous memberAppendix 1

Every check opens to its limit states, each intermediate value with its equation number, and the φ or Ω applied. Strengths come from the Direct Strength Method by default, or the Effective Width Method, in LRFD or ASD.

What you enter

  • A Z or C section by its dimensions, lipped or not, with any lip angle
  • Spans, lap lengths at each interior support, and overhangs
  • Roof slope and purlin spacing
  • Dead, roof live, snow and wind loads, with uplift
  • Anti-roll braces and other discrete braces
  • Whether the panel is through-fastened to the top flange
  • Bearing length at the rafters

How to use it

  1. 1Open the calculator and choose Purlin or girt. It starts on a lapped two-span Z-purlin.
  2. 2Set the section dimensions, spans, laps and roof slope.
  3. 3Enter the gravity loads and the wind uplift as pressures.
  4. 4Add anti-roll braces and say whether the panel is through-fastened.
  5. 5Read the governing check and click a lap end or the interior support to see the checks there.

Questions

How are lapped Z-purlins analysed?

As a continuous beam whose stiffness doubles inside each lap, where two purlins are nested. The moment over the support is shared by the two members by stiffness, and the critical points are usually the ends of the lap, where one purlin alone carries the moment, and the positive moment region of the end span.

What is the R factor for purlins?

Under wind uplift the compression flange of a through-fastened purlin is the free flange, restrained only partly by the panel. AISI S100-24 Section I6.2.1 gives the nominal strength as R times the local buckling strength of the fully braced section, with R from Table I6.2.1-1 by section type, depth and span condition, provided the listed conditions are met.

Does the calculator include torsion?

Yes. Loads applied on the flange of a Z or C act off the shear center and twist the purlin. ColdCalc runs a warping torsion analysis, reports the bimoment, and applies the Section H4 interaction of bending and torsion.

Can it check wall girts?

Yes. A girt is analysed the same way, with the wind acting as pressure and as suction. The same checks apply.

ColdCalc is a design aid. AISI S100-24 is the governing text, and results must be reviewed by the engineer responsible for the design. How the engine is tested against published examples, SSMA tables and CUFSM results is on the About page.

How the checks work