AISI S100-24 · Finite strip buckling · LRFD and ASD

Cold-formed steel design, with the work shown.

Describe a wall stud, joist, column or lapped purlin and its loads. ColdCalc builds the load combinations, analyses the member, checks every point along it to AISI S100-24, and traces each number to the clause that produced it.

  • Finite strip buckling of the real section, DSM or EWM
  • Torsion and bimoment, bracing, laps and the I6.2.1 R factor
  • 559 SSMA sections, or your own C, track, Z or hat
  • A printable calculation package for every member

Free to use while accounts open. Nothing to install.

coldcalc / wall stud
Wall stud · 600S162-54
12 ft tall · @ 16 in o.c. · 8 ASCE 7-22 combinations · AISI S100-24 LRFD
Governing ratio
0.31 OK
Axial and bending combined · at mid-height, 1.2D + W (Wind suction) + L
Axial
1.44
kip
Moment
7.20
kip·in
Deflection
L/1860
at 0.42W
bottomtop7.20−7.20moment envelope, kip·in
Axial compression
0.00 ft, 1.2D + 1.6L
0.15OK
Bending, strong axis
6.00 ft, 1.2D + W (Wind suction) + L
0.20OK
Shear
0.00 ft, 1.2D + W (Wind pressure) + L
0.04OK
Axial and bending combined
6.00 ft, 1.2D + W (Wind suction) + L
0.31OK
Bending and shear combined
6.00 ft, 1.2D + W (Wind suction) + L
0.18OK
Deflection
6.00 ft, 0.42W (Wind pressure)
0.13OK
1,647 of 1,680
member checks reach the same pass/fail as CFS 15; the other 33 trace to one safety factor
< 0.3 %
median error in effective section modulus across 775 SSMA studs and tracks
113 of 113
computable provisions of S100-24 Chapters A–H and Appendices 1–2 implemented
456
inputs, results and symbols explained in plain language
One analysis, every member

Draw the member. ColdCalc finds where it is weakest.

Each member type starts from sensible values and the same engine: loads by source, ASCE 7 combinations, an analysis with bending about both axes and warping torsion, then every S100-24 check at every support, brace and peak. Click any point of the drawing to see the checks there.

Wall studs

Axial load from above, wind as pressure and suction, bridging, and sheathing on one face, both or none.

H1 with P-δ, shear, H2, deflection at 0.42W

Joists and beams

Floor and roof framing over one span or several, with overhangs, a deck on the top flange and blocking.

Bending, shear, H2, web crippling with H3, live and total deflection

Columns

Axial loads by source, eccentric where they bear on a flange, braced at intervals, ends pinned or fixed.

E2, E3, E4; H1 when the load is eccentric; tension

Purlins and girts

Continuous, lapped Z or C members on a sloped roof, with anti-roll braces, uplift and the R factor.

Bending with torsion (H4), I6.2.1, laps shared by stiffness

Have forces from another program? Known forces checks a member for the P, M and V you type.

Buckling analysis and design, together

What used to take two programs now takes one

The usual workflow has been to run CUFSM for a section's buckling loads, then carry them into CFS or a spreadsheet to check the member. ColdCalc does both in the same step, analyses the member as well, and shows its work.
  1. 1What CUFSM does

    Finite strip buckling of the real section

    The signature curve of the section with its rounded corners, and the local and distortional modes identified by modal participation, so the right minimum is picked even when the curve has no clear dip.

    localdistortional
  2. 2What CFS does

    Every AISI S100-24 check

    Compression, bending, shear, web crippling, torsion and their interactions, by the Direct Strength or Effective Width Method, in LRFD or ASD, each value traced to its equation.

  3. 3Built in

    The member's own analysis

    Spans, laps, supports, bracing, sheathing and warping torsion under every ASCE 7 combination, so the checks run where the member is actually weakest.

Why ColdCalc

Cold-formed steel is thin, light and efficient. Checking it shouldn't be opaque.

Studs, joists and purlins are bent from sheet 0.03 to 0.10 in thick. They rarely fail by yielding: they buckle. The Specification handles that well, but its answers are only as trustworthy as your ability to see how they were reached.

Thin steel fails by buckling, and buckling is hard to check by hand

A stud can buckle as a whole, its walls can ripple locally, or a flange and lip can rotate about the corner. Hand methods approximate these. ColdCalc runs a finite strip analysis of the actual section, rounded corners included, and finds all three.

A number you can't trace is a number you can't sign

Every result names its clause. Open any check to see each limit state, every intermediate value with its equation number, and the φ or Ω applied. The calc sheet prints the whole chain.

The Specification assumes you already know it

Every input, result and symbol has an ⓘ with a plain explanation, why it matters and typical values. Guide mode puts the one-liner under every field, so the tool teaches while you use it.

Worked example

One wall stud, start to finish

This is what ColdCalc does with its starting design, in about a second. Every number below is the engine's own output, computed when this page was built.
  1. 1

    Loads by source become combinations

    ASCE 7-22 §2.3.1

    You enter each load once, without factors. ColdCalc writes the 8 strength combinations of ASCE 7-22 and the 2 service combinations for deflection, with wind pushing on the wall and pulling on it.

    1.2D + 1.6L: P = 1.44 kip·1.2D + W + L: P = 1.08 kip·w = 33.3 plf·0.9D + W·0.42W for deflection
  2. 2

    Analyse the stud

    Member analysis

    The stud spans 12 ft between its tracks. Under wind the moment peaks at mid-height and the shear at the ends; the axial force runs the full height. ColdCalc checks the supports, the bridging points and the peaks under every combination, not just one.

    Mx = wL²/8 = 7.20 kip·in·V = wL/2 = 0.20 kip·Cb = 1.01 between bridging
  3. 3

    Axial strength: three ways to buckle

    AISI S100-24 Chapter E

    The finite strip analysis finds the local buckling load of the section, Pcrℓ = 7.80 kip, well below the load that yields it (Py = 27.8 kip). Of the three limit states, local buckling interacting with global buckling is the weakest.

    Yielding and global (flexural-torsional) buckling
    §E2
    Pne = 16.70 kip
    Local buckling with global bucklingGoverns
    §E3.2
    Pnℓ = 11.17 kip
    Distortional buckling
    §E4
    Pnd = 15.02 kip
    φcPn = 0.85 × 11.17 = 9.50 kip
  4. 4

    Bending strength

    AISI S100-24 Chapter F
    Yielding and lateral-torsional buckling
    §F2.2
    Mne = 44.04 kip·in
    Local buckling with yielding and global bucklingGoverns
    §F3.2
    Mnℓ = 41.90 kip·in
    Distortional buckling
    §F4
    Mnd = 42.21 kip·in
    φbMn = 0.90 × 41.90 = 37.71 kip·in
  5. 5

    Amplify the moment for P-δ, then combine

    §C1.2.1.1, §H1.2

    The worst point is mid-height under 1.2D + W (Wind suction) + L: suction puts the flange between the bridging in compression. The axial load acting on the bowed stud adds moment, so the first-order moment is amplified by B₁ before the fractions of capacity are added.

    B1 = 1.028 →Mx = 1.028 × 7.20 = 7.40 kip·in
    P/Pa + Mx/Max= 1.08/9.50 + 7.40/37.71= 0.11 + 0.20= 0.31 ≤ 1.00 OK
  6. 6

    Shear, bending with shear, and deflection

    §G2.1, §H2, Appendix 1

    Bending with shear is checked wherever both act. Deflection uses the service combinations and the effective moment of inertia.

    V/Va = 0.20/4.71 = 0.04·H2 = 0.18·Δ = 0.077 in = L/1860 ≤ L/240
What it tells you

The stud works at 31 % of its capacity, and it is local buckling of its thin walls, not overall buckling, that limits it. There is room to go lighter: Compare sizes runs the same check on every 600-series stud and lists what passes, by weight. Print calc gives the whole chain above as a calculation package.

For beginners and experts

If you can see a number, you can ask what it means

New to cold-formed steel? Every symbol comes with a plain explanation, why it matters and typical values. Experienced? The clause and equation are right there when you want to check them.
Distortional buckling load
Pcrd

Axial load at which a flange and lip rotate about the corner (distortional buckling).

Moment gradient factor
Cb

Credit for moment that varies along the unbraced length; 1.0 is always safe.

Typical: 1.0 (conservative) to about 1.3 for a uniformly loaded segment.

Local slenderness
λℓ

√(Pne/Pcrℓ) or √(Mne/Mcrℓ). Above 0.776 local buckling reduces the strength.

Who it's for

One tool, from first check to final calc package

Structural engineers

You have a stud, joist, column or purlin from a drawing and need a defensible OK or NG.

Enter the member the way it's drawn and its loads by source, get the governing check with its clause and location, and print the calculation package for the file.

Engineers sizing members

You know the span and the load and want the lightest section that works.

Compare sizes runs your design over the 559 SSMA sections built in and ranks what passes by weight.

EITs and students

You're learning cold-formed design and the Specification reads like a wall of symbols.

Guide mode, the ⓘ on every value, and the worked calculation behind every result turn each check into a lesson.

Manufacturers and specialists

You work with custom profiles or need buckling values the tables don't give.

Define a C, track, Z or hat by its dimensions, see its properties and buckling loads, or call the same engine from your own software with 5,000 API credits a month.

What it checks

The checks that decide most cold-formed members

The engine implements every computable provision of AISI S100-24 Chapters A to H and Appendices 1 and 2. The calculator runs the ones everyday members need at every critical point of the member.
CheckWhat it coversS100-24
CompressionGlobal (flexural, torsional, flexural-torsional), local and distortional buckling§E2, §E3, §E4
BendingLateral-torsional, local and distortional buckling, about either axis§F2, §F3, §F4
ShearShear yielding and shear buckling of the web§G2
Web cripplingAt every support, end or interior one-flange loading, fastened or not§G5
TensionYielding of the gross section and rupture of the net section§D2, §D3
Axial and bendingCompression with P-δ amplification, or tension with both H1.1 equations§H1.1, §H1.2, §C1.2.1.1
Bending and shearInteraction evaluated along the span§H2
Bending and web cripplingOver interior supports, the reaction and the moment together§H3
Bending and torsionBimoment from loads off the shear center, from a warping-torsion analysis§H4, §G8.1
Through-fastened purlinsUplift strength with the R factor of Table I6.2.1-1§I6.2.1
DeflectionService-load deflection with the effective moment of inertiaAppendix 1
Dimensional limitsWidth-to-thickness and other ratios checked and flaggedTable B4.1-1
Members
  • Wall studs: axial load and wind both ways, bridging, sheathing
  • Joists, rafters and headers: one or more spans, overhangs, deck and blocking
  • Columns: axial loads with eccentricity, bracing, compression or tension
  • Purlins and girts: laps, anti-roll bracing, torsion and bimoment, uplift
  • ASCE 7-22 or 7-16 combinations generated, or your own
  • Any member, from your own P, Mx, My and V
Methods and sections
  • Direct Strength or Effective Width Method
  • Finite strip (CUFSM-equivalent) or closed-form buckling
  • LRFD or ASD; US or SI units
  • 559 SSMA studs and tracks, or a custom C, track, Z or hat
Not covered yet
  • Connections, and Chapters I to M of the Specification (except I6.2.1)
  • Sheathing-braced design and stud-to-track details (AISI S240)
  • Seismic load combinations and second-order analysis (P-δ uses the B1 amplifier)
  • Web holes and punchouts in the calculator (the engine and API support them)
  • Saved projects and team accounts (with the paid plans)
Validation

Checked against the references engineers already trust

Nearly a thousand automated tests compare ColdCalc with published examples, design tables and another program's reports. Where a result differs, the reason is found and written down, not tuned away.
  • 775 SSMA studs and tracks

    Effective section modulus against the SSMA Product Technical Guide: median error under 0.3 %, 95 % within 1.5 %, all within 3 %.

  • 482 rows of AISI Manual property tables

    C, Z, angle, hat, stud and track gross properties: median error at most 0.18 %.

  • 128 published CUFSM cases (SSRC 2011)

    Distortional buckling of Z and C sections in bending and compression: median ratio 0.998 to 1.004.

  • 420 CFS 15 reports

    About 43,600 Effective Width values agree within 0.1 %. Of 1,680 member checks, 1,647 reach the same pass/fail; the other 33 trace to CFS applying Ω = 2.0.

Worked exampleQuantityPublishedColdCalc
9CS2.5x059
AISI Design Manual
Nominal moment Mn104 kip·in104.05
8ZS2.25x059
AISI Design Manual
Mn / Pn98 kip·in / 15.0 kip98.85 / 14.97
550T125-54 track
AISI Design Manual
Nominal axial Pn9 kip9.00
3HU4.5x135 hat
AISI Design Manual
Pn / Mn87.0 kip / 76 kip·in86.82 / 75.78
362S162-54
AISI Design Manual Ex. III-3
Distortional Pcrd/Py (CUFSM)1.111.112
800S200-54
AISI Design Manual Ex. II-4
Distortional Fd with sheathing (CUFSM)60.0 ksi60.1

Some published values come from earlier editions. Where S100-24 changed an equation, the test checks the older form as a separate reference, so every input is still confirmed. The comparison also found and fixed real engine issues, each now covered by a test.

Pricing

Unlimited calculations on every plan

Pro is $29.99 a month for one engineer. Business is $100 a month for a team of 5, and $10 for each user after that. Every user also gets 5,000 API credits a month, and both plans start with a 14-day free trial.

Pro

For one engineer

$29.99a month

One user · 14-day free trial

Get started with Pro
  • Unlimited calculations in the app
  • Wall studs, joists, columns, purlins and known forces
  • Finite strip buckling, DSM and EWM, LRFD and ASD
  • ASCE 7-22 and 7-16 combinations, or your own
  • Printable calculation packages
  • 5,000 API credits a month
Best value per user

Business

For teams

$100a month for 5 users

Then $10 a month for each extra user · 14-day free trial

$100 a month, with 25,000 API credits shared by the team.

Get started with Business
  • Everything in Pro, for every user
  • 5 users included, more at $10 a month each
  • 5,000 API credits a month per user, pooled across the team
  • Top-ups go to the shared pool
  • One invoice for the team
API credits

The same engine, from your own code

Call ColdCalc from scripts, spreadsheets or your own software: check a schedule of studs overnight, size members inside a model, or build the checks into a product. Every user gets 5,000 credits a month. On Business they go into one pool, so the people who automate most can use the team's share.

  • The calculator is never metered: credits count API calls only.
  • Need more? $10 for every 10,000 credits, any time. Bought credits last 12 months.
  • The monthly allowance resets each month and is used before bought credits.
CallWhat it doesCredits
sections.*Section properties, or the effective section at a stress1
design.*A member check: compression, tension, bending, shear, web crippling, combined1
stability.*, analysis.torsionDiagramStability helpers and torsion diagrams1
buckling.*A finite strip buckling analysis: signature curve or DSM inputs2
analysis.memberDesignA member analysed and checked along its length, every combination5

5,000 credits is 5,000 member checks, or 1,000 complete member designs (analysis and every check along the member), a month for each user.

Questions

Frequently asked

Which edition of AISI S100 does it use?

AISI S100-24, the 2024 North American Specification. The engine implements all 113 computable provisions of Chapters A to H and Appendices 1 and 2, audited clause by clause against the published text.

LRFD, ASD or LSD?

The calculator offers LRFD and ASD. Enter nominal loads by source and ColdCalc builds the ASCE 7 combinations for the method you pick, or type your own combinations. Known forces takes design-level values. The engine and API also carry the Canadian LSD resistance factors.

How does it find the forces in the member?

A member analysis with exact beam elements: bending about both axes (including the coupling in a Z), axial force, and warping torsion from loads off the shear center. Supports, braces, laps, hinges and continuous restraint from sheathing are modelled, and the checks run at every support, brace, load point and peak under every combination.

Direct Strength Method or Effective Width Method?

Either. The Direct Strength Method is the default because it handles any shape; switch to the Effective Width Method in the design settings. Both are part of S100-24.

How are the buckling loads found?

By default, a finite strip analysis equivalent to CUFSM runs on the actual section, with rounded corners. Local and distortional modes are identified by their modal participation. You can also use the closed-form solutions of Appendix 2.

Can I check a section that isn't in the SSMA catalog?

Yes. Enter the dimensions of a lipped C, track, Z or hat. Through the API the engine accepts any open or closed thin-walled shape, including element-by-element definitions.

Why can results differ slightly from other programs?

Mesh density, corner modelling and a few documented method choices. For example, ColdCalc uses a converged finite strip mesh and the restrained bending stress field recommended for braced members. Each known difference is explained in the validation record.

Can I submit ColdCalc output?

ColdCalc is a design aid. Results should be reviewed by the engineer responsible for the design. The printed calculation package shows the inputs, the diagrams and every step, clause and equation, so that review is straightforward.

Are my designs stored?

Not yet. A design lives in its link, which you can bookmark or share, and in your browser's recent list. Saved projects come with accounts.

What does it cost?

Pro is $29.99 a month for one user; Business is $100 a month for 5 users and $10 a month for each one after that. Both include unlimited calculations in the app and 5,000 API credits a month per user. While accounts open, the calculator is free to use.

What is an API credit?

One call to the ColdCalc API from your own code: a member check or a section calculation is 1 credit, a finite strip analysis 2, and a complete member analysis and design 5. The calculator itself never uses credits. Extra credits are $10 for 10,000 and last 12 months.

Can my team share credits?

Yes. On Business every user's monthly credits go into one pool, so whoever runs the big batch can use the team's share, and extra credits you buy go into the same pool.

Do I need to install anything?

No. It runs in any modern browser, on a desktop, a tablet or a phone.

How is ColdCalc different from CFS and CUFSM?

CUFSM finds the elastic buckling loads of a cross-section by the finite strip method; CFS checks sections and members to AISI S100. ColdCalc does both in one place, in a browser: it analyses the member, runs a CUFSM-equivalent finite strip analysis of the section, applies every AISI S100-24 check along the member, and explains each number.

Check your next member in under a minute

Start from the 600S162-54 stud above, change it to yours, and read the answer, with the work shown.