Finite strip buckling analysis online
ColdCalc runs a finite strip elastic buckling analysis of a cold-formed steel section in the browser, the same kind of analysis CUFSM performs. It draws the signature curve, finds the local and distortional buckling loads and moments, labels the modes by modal participation, shows the buckled shape at any half-wavelength, and feeds the results straight into the Direct Strength Method checks of AISI S100-24.
What you get
This is the result for the design the calculator opens on, computed by the ColdCalc engine when this page was built. Change any input in the calculator and it reruns in about a second.
| Squash load Py | 27.82 kip | |
| Local buckling Pcrℓ | 7.81 kip | half-wavelength 4.5 in. |
| Distortional buckling Pcrd | 12.72 kip | half-wavelength 16.4 in. |
What it checks
| Check | What it covers | AISI S100-24 |
|---|---|---|
| Signature curve | Buckling load factor against half-wavelength, with the real rounded corners | Appendix 2 §2.2 |
| Local buckling | Pcrℓ and Mcrℓ, at the minimum the local modes control | §E3.2, §F3.2 |
| Distortional buckling | Pcrd and Mcrd, found by modal participation even when the curve has no clear second minimum | §E4, §F4 |
| Mode shapes | The buckled cross-section at any half-wavelength you click | Buckling tab |
| Design strengths | The buckling loads go into the Direct Strength Method with no retyping | Chapters E and F |
Every check opens to its limit states, each intermediate value with its equation number, and the φ or Ω applied. Strengths come from the Direct Strength Method by default, or the Effective Width Method, in LRFD or ASD.
What you enter
- Any of 559 SSMA studs and tracks, or a custom C, Z, track, hat or eave strut by its dimensions
- Any open shape built from a table of flat elements and corners
- The loading: axial compression, or bending about either axis
- Nothing else: the mesh, the half-wavelengths and the reference stresses are set for you
How to use it
- 1Open the calculator and pick or define the section.
- 2Open the Buckling tab in the results.
- 3Choose compression or bending about x or y.
- 4Read Pcrℓ and Pcrd (or Mcrℓ and Mcrd) off the signature curve, and click the curve to see the mode shape there.
- 5Go back to the checks: they already use these values.
Questions
Is there an online version of CUFSM?
CUFSM itself is a MATLAB program with compiled builds for Windows and Mac. ColdCalc is an independent web application whose finite strip solver computes the same quantities: signature curves, local and distortional buckling loads, mode shapes and cFSM modal participation. It is validated against published CUFSM results and runs in any browser.
What is a signature curve?
A plot of a section's elastic buckling load against the half-wavelength of the buckle. For a lipped C-section it usually has two dips: the first, at a half-wavelength close to the web depth, is local buckling; the second, at several times the depth, is distortional buckling. The load at each dip is the input the Direct Strength Method needs.
How does ColdCalc tell local from distortional buckling?
By modal participation from the constrained finite strip method: each buckling mode is split into its global, distortional and local parts, and the minimum is labelled by which part dominates. This finds the right load even when the signature curve has no distinct minimum. The CUFSM two-minima rule is available as an alternative.
How accurate is the finite strip analysis?
Across 128 published CUFSM cases for distortional buckling of C and Z sections (SSRC 2011), the median ratio of ColdCalc to the published value is between 0.998 and 1.004. The solver's algorithms are also tested against reference implementations faithful to CUFSM.
ColdCalc is a design aid. AISI S100-24 is the governing text, and results must be reviewed by the engineer responsible for the design. How the engine is tested against published examples, SSMA tables and CUFSM results is on the About page.
How the checks work
The finite strip method and the signature curve: what CUFSM computes, and how to read it
How the finite strip method finds a section's buckling loads, what the signature curve and cFSM modal identification show, and how the results feed the Direct Strength Method.
Local, distortional and global buckling of cold-formed steel, explained
The three ways a thin-walled steel member buckles, how to tell them apart on a signature curve, and how AISI S100-24 turns each into a strength. With finite strip results for a real stud.
The Direct Strength Method in AISI S100-24, with a worked example
The S100-24 Direct Strength Method step by step: elastic buckling loads, slenderness, the new rational strength equations, and a full column example with every number shown.