AISI S100-24 member check from known forces
When the forces come from a frame analysis or another program, ColdCalc checks the member for them directly. Enter the required axial force, moments about both axes and shear, with the unbraced lengths, and it returns the available strengths and the interaction checks of AISI S100-24 for the section.
What you get
This is the result for the design the calculator opens on, computed by the ColdCalc engine when this page was built. Change any input in the calculator and it reruns in about a second.
| Check | S100-24 | Ratio | ||
|---|---|---|---|---|
| Axial compression | §E2, §E3.2, §E4 | 0.13 | OK | |
| Bending, strong axis | §F2.2, §F3.2, §F4 | 0.64 | OK | |
| Axial and bending combined | §H1.2, Eq. H1.2-1 | 0.76 | OK | |
| Shear | §G2.1 | 0.21 | OK | |
| Bending and shear combined | §H2, Eq. H2-1 | 0.63 | OK |
600S162-54, Fy = 50 ksi, with P = 1.20 kip, Mx = 24.0 kip·in and V = 1.00 kip; KxLx = 12 ft, KyLy = KtLt = 4 ft. AISI S100-24 LRFD, Direct Strength Method. A ratio is demand over available strength, or an interaction value over its limit; 1.00 or less passes.
What it checks
| Check | What it covers | AISI S100-24 |
|---|---|---|
| Compression or tension | Chapter E or Chapter D strength of the section for your lengths | §E2, §E3, §E4, §D2, §D3 |
| Bending about each axis | With your unbraced length and Cb | §F2, §F3, §F4 |
| Shear | Web shear strength | §G2 |
| Web crippling | For a bearing length and load case you choose | §G5 |
| Combined actions | Axial with bending, bending with shear, bending with web crippling | §H1, §H2, §H3 |
Every check opens to its limit states, each intermediate value with its equation number, and the φ or Ω applied. Strengths come from the Direct Strength Method by default, or the Effective Width Method, in LRFD or ASD.
What you enter
- The section and steel grade
- Required P (compression or tension), Mx, My and V at design level
- Unbraced lengths KxLx, KyLy and KtLt, and the moment gradient factor Cb
- Which flange each moment compresses
- LRFD or ASD, and the Direct Strength or Effective Width Method
How to use it
- 1Open the calculator and choose Known forces.
- 2Pick the section and method.
- 3Type the required forces and the unbraced lengths.
- 4Read each strength and interaction, and open any row for its limit states and equations.
Questions
Should the forces be factored?
Yes. Known forces takes design-level values: factored loads for LRFD, or service-level combination results for ASD. The other member types take loads by source and build the combinations for you.
Does it amplify the moments for second-order effects?
Optionally. If your forces come from a first-order analysis, turn on amplification and the moments are multiplied by B1 for P-δ (Section C1.2.1.1). If they come from a second-order analysis, leave it off.
Can I use my own elastic buckling values?
Through the API, yes: Pcrℓ, Pcrd, Mcrℓ, Mcrd, Pcre and Mcre supplied by you override the finite strip or analytical values. In the calculator the values come from the finite strip analysis or Appendix 2.
ColdCalc is a design aid. AISI S100-24 is the governing text, and results must be reviewed by the engineer responsible for the design. How the engine is tested against published examples, SSMA tables and CUFSM results is on the About page.
How the checks work
The Direct Strength Method in AISI S100-24, with a worked example
The S100-24 Direct Strength Method step by step: elastic buckling loads, slenderness, the new rational strength equations, and a full column example with every number shown.
Effective Width Method vs Direct Strength Method: when they differ, and why
How the two AISI S100 methods model local and distortional buckling, where their answers diverge for studs and tracks, and how to choose between them.
Cold-formed steel design: a practical guide to AISI S100-24
How cold-formed steel studs, joists, columns and purlins are designed to AISI S100-24: buckling modes, DSM and EWM, load combinations, the checks that govern, and where to start.