1400S162-97 stud properties and strength

SSMA 14 in stud or joist, 1-5/8 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1400S162-97 has an area of 1.779 in² and weighs 6.05 lb/ft. Its strong-axis moment of inertia is 40.116 in⁴ gross and 36.991 in⁴ effective at yield, and its effective section modulus is 4.915 in³. With the flange braced, its allowable moment is 138.7 kip·in (ASD), governed by distortional buckling (§F4).

14″1-5/8″0.5″ lipt = 0.1017″

Dimensions

Depth14in
Flange width1-5/8in
Lip length0.5in
Design thickness0.1017in
Minimum thickness0.0966in
Inside bend radius0.1526in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.779in²
Weight6.05lb/ft
Ix40.116in⁴
Sx5.731in³
rx4.748in
Iy0.341in⁴
Sy0.247in³
ry0.438in

Torsion and effective section

J6.134×10⁻³ in⁴
Cw13.320in⁶
xo-0.613in
ro4.808in
β0.984
Ixe at yield36.991in⁴
Sxe4.915in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)231.61138.69208.45§F4 · kip·in
Strong-axis moment, flange braced (EWM)231.50138.62208.35§F4 · kip·in
Shear, web without holes15.869.5014.28§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)21.5711.9818.34§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)21.5711.9818.34§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)21.5711.9818.34§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)21.5711.9818.34§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)21.5711.9818.34§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)21.5711.9818.34§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (P/Py)Local0.13 at 15.1 inDistortional (by cFSM)0.14 at 21.0 in
Signature curve of the 1400S162-97 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (M/My)Local0.77 at 11.5 inDistortional (by cFSM)0.81 at 15.0 in
Signature curve of the 1400S162-97 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py88.96kip
Pcrℓ at 15.111.81kip
Pcrd at 21.012.83kip
My286.54kip·in
Mcrℓ at 11.5220.46kip·in
Mcrd at 15.0231.33kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
11.81 kip at 15.1 in
Distortional
12.83 kip at 21.0 in
Buckled shapes of the 1400S162-97 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1400S162-97 mean?

1400S162-97 is an SSMA designation: 14 in stud or joist, 1-5/8 in flange, 97 mil (0.1017 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.

What are the section properties of a 1400S162-97 stud?

Area 1.779 in², weight 6.05 lb/ft, Ix 40.116 in⁴, Sx 5.731 in³, rx 4.748 in, Iy 0.341 in⁴, ry 0.438 in, J 6.134 ×10⁻³ in⁴, Cw 13.320 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1400S162-97?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 231.6 kip·in by the Direct Strength Method (governed by §F4): 138.7 kip·in allowable (ASD) or 208.4 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1400S162-97?

By finite strip analysis, local buckling in compression occurs at 11.81 kip (half-wavelength 15.1 in) and distortional buckling at 12.83 kip (21.0 in), against a squash load Py of 88.96 kip.

Other 14 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation