800T300-97 track properties and strength

SSMA 8 in track, 3 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 800T300-97 has an area of 1.406 in² and weighs 4.78 lb/ft. Its strong-axis moment of inertia is 14.054 in⁴ gross and 11.476 in⁴ effective at yield, and its effective section modulus is 2.520 in³. With the flange braced, its allowable moment is 72.2 kip·in (ASD), governed by local buckling (§F3).

8-1/4″3″t = 0.1017″

Dimensions

Depth (inside)8in
Flange width3in
Design thickness0.1017in
Minimum thickness0.0966in
Inside bend radius0.1526in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.406in²
Weight4.78lb/ft
Ix14.054in⁴
Sx3.426in³
rx3.162in
Iy1.182in⁴
Sy0.510in³
ry0.917in

Torsion and effective section

J4.848×10⁻³ in⁴
Cw13.488in⁶
xo-1.660in
ro3.687in
β0.797
Ixe at yield11.476in⁴
Sxe2.520in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)120.5672.19108.50§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)126.0075.45113.40§F3.1 · kip·in
Shear, web without holes16.6910.0015.02§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)35.9819.9930.58§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)35.9719.9830.57§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)35.9519.9730.56§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)35.8919.9430.50§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)35.6819.8230.33§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)34.9219.4029.68§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.34 at 9.1 in
Signature curve of the 800T300-97 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (M/My)Local0.57 at 7.0 in
Signature curve of the 800T300-97 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py70.30kip
Pcrℓ at 9.123.62kip
My171.32kip·in
Mcrℓ at 7.097.96kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
23.62 kip at 9.1 in
Buckled shapes of the 800T300-97 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 800T300-97 mean?

800T300-97 is an SSMA designation: 8 in track, 3 in flange, 97 mil (0.1017 in). The first number is the inside depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.

What are the section properties of a 800T300-97 track?

Area 1.406 in², weight 4.78 lb/ft, Ix 14.054 in⁴, Sx 3.426 in³, rx 3.162 in, Iy 1.182 in⁴, ry 0.917 in, J 4.848 ×10⁻³ in⁴, Cw 13.488 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 800T300-97?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 120.6 kip·in by the Direct Strength Method (governed by §F3.2): 72.2 kip·in allowable (ASD) or 108.5 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 800T300-97?

By finite strip analysis, local buckling in compression occurs at 23.62 kip (half-wavelength 9.1 in), against a squash load Py of 70.30 kip.

Other 8 in tracks

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation