800T125-43 track properties and strength

SSMA 8 in track, 1-1/4 in flange, 43 mil (0.0451 in), Grade 33 (ASTM A1003 ST33H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 800T125-43 has an area of 0.470 in² and weighs 1.60 lb/ft. Its strong-axis moment of inertia is 3.689 in⁴ gross and 2.956 in⁴ effective at yield, and its effective section modulus is 0.634 in³. With the flange braced, its allowable moment is 13.8 kip·in (ASD), governed by local buckling (§F3).

8-1/8″1-1/4″t = 0.0451″

Dimensions

Depth (inside)8in
Flange width1-1/4in
Design thickness0.0451in
Minimum thickness0.0428in
Inside bend radius0.0712in
Yield stress Fy33ksi
Tensile strength Fu45ksi

Gross properties

Area A0.470in²
Weight1.60lb/ft
Ix3.689in⁴
Sx0.912in³
rx2.802in
Iy0.046in⁴
Sy0.042in³
ry0.312in

Torsion and effective section

J0.319×10⁻³ in⁴
Cw0.570in⁶
xo-0.443in
ro2.854in
β0.976
Ixe at yield2.956in⁴
Sxe0.634in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)23.1113.8420.80§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)20.9312.5418.84§F3.1 · kip·in
Shear, web without holes2.471.482.22§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)3.051.702.59§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)3.051.702.59§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)3.051.702.59§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)3.051.702.59§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)3.051.702.59§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)3.051.702.59§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.12 at 8.0 in
Signature curve of the 800T125-43 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (M/My)Local0.59 at 5.6 in
Signature curve of the 800T125-43 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py15.51kip
Pcrℓ at 8.01.79kip
My30.10kip·in
Mcrℓ at 5.617.61kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
1.79 kip at 8.0 in
Buckled shapes of the 800T125-43 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 800T125-43 mean?

800T125-43 is an SSMA designation: 8 in track, 1-1/4 in flange, 43 mil (0.0451 in). The first number is the inside depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0451 in.

What are the section properties of a 800T125-43 track?

Area 0.470 in², weight 1.60 lb/ft, Ix 3.689 in⁴, Sx 0.912 in³, rx 2.802 in, Iy 0.046 in⁴, ry 0.312 in, J 0.319 ×10⁻³ in⁴, Cw 0.570 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 800T125-43?

With the compression flange braced against lateral-torsional buckling and Fy = 33 ksi, AISI S100-24 gives a nominal strong-axis moment of 23.1 kip·in by the Direct Strength Method (governed by §F3.2): 13.8 kip·in allowable (ASD) or 20.8 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 800T125-43?

By finite strip analysis, local buckling in compression occurs at 1.79 kip (half-wavelength 8.0 in), against a squash load Py of 15.51 kip.

Other 8 in tracks

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation