800T200-97 track properties and strength

SSMA 8 in track, 2 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 800T200-97 has an area of 1.203 in² and weighs 4.09 lb/ft. Its strong-axis moment of inertia is 10.716 in⁴ gross and 9.836 in⁴ effective at yield, and its effective section modulus is 2.295 in³. With the flange braced, its allowable moment is 71.2 kip·in (ASD), governed by local buckling (§F3).

8-1/4″2″t = 0.1017″

Dimensions

Depth (inside)8in
Flange width2in
Design thickness0.1017in
Minimum thickness0.0966in
Inside bend radius0.1526in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.203in²
Weight4.09lb/ft
Ix10.716in⁴
Sx2.613in³
rx2.985in
Iy0.378in⁴
Sy0.232in³
ry0.560in

Torsion and effective section

J4.146×10⁻³ in⁴
Cw4.454in⁶
xo-0.912in
ro3.171in
β0.917
Ixe at yield9.836in⁴
Sxe2.295in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)118.9371.22107.04§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)114.7768.72103.29§F3.1 · kip·in
Shear, web without holes16.6910.0015.02§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)26.5214.7422.55§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)26.5214.7422.55§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)26.5214.7422.55§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)26.5214.7422.55§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)26.5214.7422.55§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)26.5214.7422.55§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.38 at 8.2 in
Signature curve of the 800T200-97 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.01101001000half-wavelength, in (log scale)load factor (M/My)Local1.20 at 5.5 in
Signature curve of the 800T200-97 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py60.13kip
Pcrℓ at 8.222.83kip
My130.63kip·in
Mcrℓ at 5.5156.71kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
22.83 kip at 8.2 in
Buckled shapes of the 800T200-97 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 800T200-97 mean?

800T200-97 is an SSMA designation: 8 in track, 2 in flange, 97 mil (0.1017 in). The first number is the inside depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.

What are the section properties of a 800T200-97 track?

Area 1.203 in², weight 4.09 lb/ft, Ix 10.716 in⁴, Sx 2.613 in³, rx 2.985 in, Iy 0.378 in⁴, ry 0.560 in, J 4.146 ×10⁻³ in⁴, Cw 4.454 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 800T200-97?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 118.9 kip·in by the Direct Strength Method (governed by §F3.2): 71.2 kip·in allowable (ASD) or 107.0 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 800T200-97?

By finite strip analysis, local buckling in compression occurs at 22.83 kip (half-wavelength 8.2 in), against a squash load Py of 60.13 kip.

Other 8 in tracks

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation