800S350-54 stud properties and strength

SSMA 8 in stud or joist, 3-1/2 in flange, 54 mil (0.0566 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 800S350-54 has an area of 0.938 in² and weighs 3.19 lb/ft. Its strong-axis moment of inertia is 9.683 in⁴ gross and 8.279 in⁴ effective at yield, and its effective section modulus is 1.872 in³. With the flange braced, its allowable moment is 51.6 kip·in (ASD), governed by distortional buckling (§F4).

8″3-1/2″1″ lipt = 0.0566″

Dimensions

Depth8in
Flange width3-1/2in
Lip length1in
Design thickness0.0566in
Minimum thickness0.0538in
Inside bend radius0.0849in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A0.938in²
Weight3.19lb/ft
Ix9.683in⁴
Sx2.421in³
rx3.212in
Iy1.646in⁴
Sy0.694in³
ry1.325in

Torsion and effective section

J1.002×10⁻³ in⁴
Cw22.352in⁶
xo-2.764in
ro4.440in
β0.612
Ixe at yield8.279in⁴
Sxe1.872in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)86.1751.6077.56§F4 · kip·in
Strong-axis moment, flange braced (EWM)86.1651.6077.55§F4 · kip·in
Shear, web without holes4.862.914.38§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)18.4110.2315.65§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)18.3810.2115.62§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)18.3410.1915.59§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)18.1510.0815.43§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)17.739.8515.07§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)17.169.5314.58§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.15 at 6.2 inDistortional0.43 at 43.0 in
Signature curve of the 800S350-54 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (M/My)Local0.66 at 4.0 inDistortional0.79 at 39.5 in
Signature curve of the 800S350-54 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py46.92kip
Pcrℓ at 6.27.06kip
Pcrd at 43.020.32kip
My121.04kip·in
Mcrℓ at 4.079.33kip·in
Mcrd at 39.596.12kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
7.06 kip at 6.2 in
Distortional
20.32 kip at 43.0 in
Buckled shapes of the 800S350-54 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 800S350-54 mean?

800S350-54 is an SSMA designation: 8 in stud or joist, 3-1/2 in flange, 54 mil (0.0566 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0566 in.

What are the section properties of a 800S350-54 stud?

Area 0.938 in², weight 3.19 lb/ft, Ix 9.683 in⁴, Sx 2.421 in³, rx 3.212 in, Iy 1.646 in⁴, ry 1.325 in, J 1.002 ×10⁻³ in⁴, Cw 22.352 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 800S350-54?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 86.2 kip·in by the Direct Strength Method (governed by §F4): 51.6 kip·in allowable (ASD) or 77.6 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 800S350-54?

By finite strip analysis, local buckling in compression occurs at 7.06 kip (half-wavelength 6.2 in) and distortional buckling at 20.32 kip (43.0 in), against a squash load Py of 46.92 kip.

Other 8 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation