800S200-43 stud properties and strength

SSMA 8 in stud or joist, 2 in flange, 43 mil (0.0451 in), Grade 33 (ASTM A1003 ST33H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 800S200-43 has an area of 0.582 in² and weighs 1.98 lb/ft. Its strong-axis moment of inertia is 5.302 in⁴ gross and 5.224 in⁴ effective at yield, and its effective section modulus is 1.294 in³. With the flange braced, its allowable moment is 21.1 kip·in (ASD), governed by local buckling (§F3).

8″2″0.625″ lipt = 0.0451″

Dimensions

Depth8in
Flange width2in
Lip length0.625in
Design thickness0.0451in
Minimum thickness0.0428in
Inside bend radius0.0712in
Yield stress Fy33ksi
Tensile strength Fu45ksi

Gross properties

Area A0.582in²
Weight1.98lb/ft
Ix5.302in⁴
Sx1.325in³
rx3.018in
Iy0.292in⁴
Sy0.193in³
ry0.708in

Torsion and effective section

J0.395×10⁻³ in⁴
Cw3.677in⁶
xo-1.273in
ro3.351in
β0.856
Ixe at yield5.224in⁴
Sxe1.294in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)35.2221.0931.70§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)37.0422.1833.34§F4 · kip·in
Shear, web without holes2.481.492.24§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)7.254.036.16§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)7.254.036.16§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)7.254.036.16§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)7.254.036.16§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)7.254.036.16§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)7.254.036.16§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.15 at 5.9 inDistortional (by cFSM)0.35 at 26.2 in
Signature curve of the 800S200-43 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.01101001000half-wavelength, in (log scale)load factor (M/My)Local0.83 at 4.3 inDistortional1.22 at 21.6 in
Signature curve of the 800S200-43 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py19.21kip
Pcrℓ at 5.92.92kip
Pcrd at 26.26.65kip
My43.74kip·in
Mcrℓ at 4.336.14kip·in
Mcrd at 21.653.14kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
2.92 kip at 5.9 in
Distortional
6.65 kip at 26.2 in
Buckled shapes of the 800S200-43 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 800S200-43 mean?

800S200-43 is an SSMA designation: 8 in stud or joist, 2 in flange, 43 mil (0.0451 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0451 in.

What are the section properties of a 800S200-43 stud?

Area 0.582 in², weight 1.98 lb/ft, Ix 5.302 in⁴, Sx 1.325 in³, rx 3.018 in, Iy 0.292 in⁴, ry 0.708 in, J 0.395 ×10⁻³ in⁴, Cw 3.677 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 800S200-43?

With the compression flange braced against lateral-torsional buckling and Fy = 33 ksi, AISI S100-24 gives a nominal strong-axis moment of 35.2 kip·in by the Direct Strength Method (governed by §F3.2): 21.1 kip·in allowable (ASD) or 31.7 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 800S200-43?

By finite strip analysis, local buckling in compression occurs at 2.92 kip (half-wavelength 5.9 in) and distortional buckling at 6.65 kip (26.2 in), against a squash load Py of 19.21 kip.

Other 8 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation