800S200-97 stud properties and strength

SSMA 8 in stud or joist, 2 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 800S200-97 has an area of 1.271 in² and weighs 4.32 lb/ft. Its strong-axis moment of inertia is 11.204 in⁴ gross and 11.204 in⁴ effective at yield, and its effective section modulus is 2.801 in³. With the flange braced, its allowable moment is 82.2 kip·in (ASD), governed by distortional buckling (§F4).

8″2″0.625″ lipt = 0.1017″

Dimensions

Depth8in
Flange width2in
Lip length0.625in
Design thickness0.1017in
Minimum thickness0.0966in
Inside bend radius0.1526in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.271in²
Weight4.32lb/ft
Ix11.204in⁴
Sx2.801in³
rx2.969in
Iy0.577in⁴
Sy0.381in³
ry0.674in

Torsion and effective section

J4.381×10⁻³ in⁴
Cw7.094in⁶
xo-1.202in
ro3.274in
β0.865
Ixe at yield11.204in⁴
Sxe2.801in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)137.2882.21123.56§F4 · kip·in
Strong-axis moment, flange braced (EWM)137.2682.19123.53§F4 · kip·in
Shear, web without holes16.619.9414.95§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)34.3519.0829.20§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)34.3519.0829.20§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)34.3519.0829.20§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)34.3519.0829.20§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)34.3519.0829.20§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)34.3519.0829.20§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.51 at 6.3 inDistortional (by cFSM)0.62 at 17.2 in
Signature curve of the 800S200-97 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.04.55.05.56.06.51101001000half-wavelength, in (log scale)load factor (M/My)Local2.80 at 4.6 inDistortional2.16 at 13.4 in
Signature curve of the 800S200-97 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py63.53kip
Pcrℓ at 6.332.30kip
Pcrd at 17.239.59kip
My140.05kip·in
Mcrℓ at 4.6392.44kip·in
Mcrd at 13.4303.03kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
32.30 kip at 6.3 in
Distortional
39.59 kip at 17.2 in
Buckled shapes of the 800S200-97 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 800S200-97 mean?

800S200-97 is an SSMA designation: 8 in stud or joist, 2 in flange, 97 mil (0.1017 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.

What are the section properties of a 800S200-97 stud?

Area 1.271 in², weight 4.32 lb/ft, Ix 11.204 in⁴, Sx 2.801 in³, rx 2.969 in, Iy 0.577 in⁴, ry 0.674 in, J 4.381 ×10⁻³ in⁴, Cw 7.094 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 800S200-97?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 137.3 kip·in by the Direct Strength Method (governed by §F4): 82.2 kip·in allowable (ASD) or 123.6 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 800S200-97?

By finite strip analysis, local buckling in compression occurs at 32.30 kip (half-wavelength 6.3 in) and distortional buckling at 39.59 kip (17.2 in), against a squash load Py of 63.53 kip.

Other 8 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation