550S250-54 stud properties and strength

SSMA 5-1/2 in stud or joist, 2-1/2 in flange, 54 mil (0.0566 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 550S250-54 has an area of 0.641 in² and weighs 2.18 lb/ft. Its strong-axis moment of inertia is 3.126 in⁴ gross and 2.804 in⁴ effective at yield, and its effective section modulus is 0.952 in³. With the flange braced, its allowable moment is 26.6 kip·in (ASD), governed by distortional buckling (§F4).

5-1/2″2-1/2″0.625″ lipt = 0.0566″

Dimensions

Depth5-1/2in
Flange width2-1/2in
Lip length0.625in
Design thickness0.0566in
Minimum thickness0.0538in
Inside bend radius0.0849in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A0.641in²
Weight2.18lb/ft
Ix3.126in⁴
Sx1.137in³
rx2.208in
Iy0.547in⁴
Sy0.320in³
ry0.923in

Torsion and effective section

J0.685×10⁻³ in⁴
Cw3.355in⁶
xo-1.915in
ro3.065in
β0.610
Ixe at yield2.804in⁴
Sxe0.952in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)44.3826.5739.94§F4 · kip·in
Strong-axis moment, flange braced (EWM)44.3726.5739.93§F4 · kip·in
Shear, web without holes5.263.154.74§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)15.308.5013.01§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)15.268.4812.97§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)15.188.4412.91§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)14.858.2512.62§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)14.107.8411.99§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)13.087.2711.12§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.32 at 4.3 inDistortional0.60 at 22.9 in
Signature curve of the 550S250-54 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.01101001000half-wavelength, in (log scale)load factor (M/My)Local1.33 at 2.8 inDistortional1.06 at 21.2 in
Signature curve of the 550S250-54 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py32.06kip
Pcrℓ at 4.310.25kip
Pcrd at 22.919.29kip
My56.83kip·in
Mcrℓ at 2.875.69kip·in
Mcrd at 21.259.96kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
10.25 kip at 4.3 in
Distortional
19.29 kip at 22.9 in
Buckled shapes of the 550S250-54 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 550S250-54 mean?

550S250-54 is an SSMA designation: 5-1/2 in stud or joist, 2-1/2 in flange, 54 mil (0.0566 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0566 in.

What are the section properties of a 550S250-54 stud?

Area 0.641 in², weight 2.18 lb/ft, Ix 3.126 in⁴, Sx 1.137 in³, rx 2.208 in, Iy 0.547 in⁴, ry 0.923 in, J 0.685 ×10⁻³ in⁴, Cw 3.355 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 550S250-54?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 44.4 kip·in by the Direct Strength Method (governed by §F4): 26.6 kip·in allowable (ASD) or 39.9 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 550S250-54?

By finite strip analysis, local buckling in compression occurs at 10.25 kip (half-wavelength 4.3 in) and distortional buckling at 19.29 kip (22.9 in), against a squash load Py of 32.06 kip.

Other 5-1/2 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation