550S200-43 stud properties and strength

SSMA 5-1/2 in stud or joist, 2 in flange, 43 mil (0.0451 in), Grade 33 (ASTM A1003 ST33H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 550S200-43 has an area of 0.469 in² and weighs 1.60 lb/ft. Its strong-axis moment of inertia is 2.189 in⁴ gross and 2.157 in⁴ effective at yield, and its effective section modulus is 0.777 in³. With the flange braced, its allowable moment is 14.1 kip·in (ASD), governed by distortional buckling (§F4).

5-1/2″2″0.625″ lipt = 0.0451″

Dimensions

Depth5-1/2in
Flange width2in
Lip length0.625in
Design thickness0.0451in
Minimum thickness0.0428in
Inside bend radius0.0712in
Yield stress Fy33ksi
Tensile strength Fu45ksi

Gross properties

Area A0.469in²
Weight1.60lb/ft
Ix2.189in⁴
Sx0.796in³
rx2.159in
Iy0.261in⁴
Sy0.187in³
ry0.746in

Torsion and effective section

J0.318×10⁻³ in⁴
Cw1.635in⁶
xo-1.494in
ro2.730in
β0.700
Ixe at yield2.157in⁴
Sxe0.777in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)23.5014.0721.15§F4 · kip·in
Strong-axis moment, flange braced (EWM)23.5014.0721.15§F4 · kip·in
Shear, web without holes2.711.622.44§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)7.684.276.53§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)7.674.266.52§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)7.664.256.51§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)7.584.216.44§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)7.374.096.26§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)7.013.905.96§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.31 at 4.2 inDistortional0.76 at 21.7 in
Signature curve of the 550S200-43 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.01101001000half-wavelength, in (log scale)load factor (M/My)Local1.59 at 3.0 inDistortional1.68 at 20.5 in
Signature curve of the 550S200-43 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py15.49kip
Pcrℓ at 4.24.85kip
Pcrd at 21.711.78kip
My26.26kip·in
Mcrℓ at 3.041.79kip·in
Mcrd at 20.544.01kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
4.85 kip at 4.2 in
Distortional
11.78 kip at 21.7 in
Buckled shapes of the 550S200-43 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 550S200-43 mean?

550S200-43 is an SSMA designation: 5-1/2 in stud or joist, 2 in flange, 43 mil (0.0451 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0451 in.

What are the section properties of a 550S200-43 stud?

Area 0.469 in², weight 1.60 lb/ft, Ix 2.189 in⁴, Sx 0.796 in³, rx 2.159 in, Iy 0.261 in⁴, ry 0.746 in, J 0.318 ×10⁻³ in⁴, Cw 1.635 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 550S200-43?

With the compression flange braced against lateral-torsional buckling and Fy = 33 ksi, AISI S100-24 gives a nominal strong-axis moment of 23.5 kip·in by the Direct Strength Method (governed by §F4): 14.1 kip·in allowable (ASD) or 21.2 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 550S200-43?

By finite strip analysis, local buckling in compression occurs at 4.85 kip (half-wavelength 4.2 in) and distortional buckling at 11.78 kip (21.7 in), against a squash load Py of 15.49 kip.

Other 5-1/2 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation