550S200-54 stud properties and strength

SSMA 5-1/2 in stud or joist, 2 in flange, 54 mil (0.0566 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 550S200-54 has an area of 0.585 in² and weighs 1.99 lb/ft. Its strong-axis moment of inertia is 2.706 in⁴ gross and 2.572 in⁴ effective at yield, and its effective section modulus is 0.904 in³. With the flange braced, its allowable moment is 25.5 kip·in (ASD), governed by distortional buckling (§F4).

5-1/2″2″0.625″ lipt = 0.0566″

Dimensions

Depth5-1/2in
Flange width2in
Lip length0.625in
Design thickness0.0566in
Minimum thickness0.0538in
Inside bend radius0.0849in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A0.585in²
Weight1.99lb/ft
Ix2.706in⁴
Sx0.984in³
rx2.152in
Iy0.320in⁴
Sy0.228in³
ry0.739in

Torsion and effective section

J0.624×10⁻³ in⁴
Cw1.987in⁶
xo-1.479in
ro2.714in
β0.703
Ixe at yield2.572in⁴
Sxe0.904in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)42.5825.5038.32§F4 · kip·in
Strong-axis moment, flange braced (EWM)42.5725.4938.32§F4 · kip·in
Shear, web without holes5.263.154.74§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)13.627.5711.58§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)13.597.5511.55§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)13.557.5311.52§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)13.347.4111.34§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)12.747.0810.83§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)11.796.5510.02§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.33 at 4.2 inDistortional0.65 at 19.0 in
Signature curve of the 550S200-54 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.01101001000half-wavelength, in (log scale)load factor (M/My)Local1.67 at 3.0 inDistortional1.43 at 18.0 in
Signature curve of the 550S200-54 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py29.23kip
Pcrℓ at 4.29.57kip
Pcrd at 19.018.96kip
My49.21kip·in
Mcrℓ at 3.081.98kip·in
Mcrd at 18.070.58kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
9.57 kip at 4.2 in
Distortional
18.96 kip at 19.0 in
Buckled shapes of the 550S200-54 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 550S200-54 mean?

550S200-54 is an SSMA designation: 5-1/2 in stud or joist, 2 in flange, 54 mil (0.0566 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0566 in.

What are the section properties of a 550S200-54 stud?

Area 0.585 in², weight 1.99 lb/ft, Ix 2.706 in⁴, Sx 0.984 in³, rx 2.152 in, Iy 0.320 in⁴, ry 0.739 in, J 0.624 ×10⁻³ in⁴, Cw 1.987 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 550S200-54?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 42.6 kip·in by the Direct Strength Method (governed by §F4): 25.5 kip·in allowable (ASD) or 38.3 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 550S200-54?

By finite strip analysis, local buckling in compression occurs at 9.57 kip (half-wavelength 4.2 in) and distortional buckling at 18.96 kip (19.0 in), against a squash load Py of 29.23 kip.

Other 5-1/2 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation