1200S300-118 stud properties and strength

SSMA 12 in stud or joist, 3 in flange, 118 mil (0.1242 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1200S300-118 has an area of 2.276 in² and weighs 7.75 lb/ft. Its strong-axis moment of inertia is 45.107 in⁴ gross and 44.080 in⁴ effective at yield, and its effective section modulus is 7.248 in³. With the flange braced, its allowable moment is 196.3 kip·in (ASD), governed by distortional buckling (§F4).

12″3″0.625″ lipt = 0.1242″

Dimensions

Depth12in
Flange width3in
Lip length0.625in
Design thickness0.1242in
Minimum thickness0.1180in
Inside bend radius0.1863in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A2.276in²
Weight7.75lb/ft
Ix45.107in⁴
Sx7.518in³
rx4.452in
Iy2.096in⁴
Sy0.894in³
ry0.960in

Torsion and effective section

J11.704×10⁻³ in⁴
Cw55.739in⁶
xo-1.648in
ro4.843in
β0.884
Ixe at yield44.080in⁴
Sxe7.248in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)327.81196.29295.03§F4 · kip·in
Strong-axis moment, flange braced (EWM)327.71196.23294.94§F4 · kip·in
Shear, web without holes25.3415.1722.80§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)55.7930.9947.42§E4 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)55.7930.9947.42§E4 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)55.7930.9947.42§E4 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)55.7930.9947.42§E4 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)55.7930.9947.42§E4 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)55.7930.9947.42§E4 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (P/Py)Local0.33 at 10.3 inDistortional (by cFSM)0.38 at 23.0 in
Signature curve of the 1200S300-118 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.0101001000half-wavelength, in (log scale)load factor (M/My)Local (by cFSM)1.81 at 6.3 inDistortional1.30 at 17.1 in
Signature curve of the 1200S300-118 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py113.81kip
Pcrℓ at 10.337.01kip
Pcrd at 23.043.04kip
My375.89kip·in
Mcrℓ at 6.3678.59kip·in
Mcrd at 17.1488.14kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
37.01 kip at 10.3 in
Distortional
43.04 kip at 23.0 in
Buckled shapes of the 1200S300-118 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1200S300-118 mean?

1200S300-118 is an SSMA designation: 12 in stud or joist, 3 in flange, 118 mil (0.1242 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1242 in.

What are the section properties of a 1200S300-118 stud?

Area 2.276 in², weight 7.75 lb/ft, Ix 45.107 in⁴, Sx 7.518 in³, rx 4.452 in, Iy 2.096 in⁴, ry 0.960 in, J 11.704 ×10⁻³ in⁴, Cw 55.739 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1200S300-118?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 327.8 kip·in by the Direct Strength Method (governed by §F4): 196.3 kip·in allowable (ASD) or 295.0 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1200S300-118?

By finite strip analysis, local buckling in compression occurs at 37.01 kip (half-wavelength 10.3 in) and distortional buckling at 43.04 kip (23.0 in), against a squash load Py of 113.81 kip.

Other 12 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation