1200S200-33 stud properties and strength
SSMA 12 in stud or joist, 2 in flange, 33 mil (0.0346 in), Grade 33 (ASTM A1003 ST33H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.
The 1200S200-33 has an area of 0.586 in² and weighs 2.00 lb/ft. Its strong-axis moment of inertia is 10.965 in⁴ gross and 8.555 in⁴ effective at yield, and its effective section modulus is 1.186 in³. With the flange braced, its allowable moment is 15.6 kip·in (ASD), governed by local buckling (§F3).
Dimensions
| Depth | 12 | in |
| Flange width | 2 | in |
| Lip length | 0.625 | in |
| Design thickness | 0.0346 | in |
| Minimum thickness | 0.0329 | in |
| Inside bend radius | 0.0765 | in |
| Yield stress Fy | 33 | ksi |
| Tensile strength Fu | 45 | ksi |
Gross properties
| Area A | 0.586 | in² |
| Weight | 2.00 | lb/ft |
| Ix | 10.965 | in⁴ |
| Sx | 1.827 | in³ |
| rx | 4.324 | in |
| Iy | 0.251 | in⁴ |
| Sy | 0.155 | in³ |
| ry | 0.654 | in |
Torsion and effective section
| J | 0.234 | ×10⁻³ in⁴ |
| Cw | 7.117 | in⁶ |
| xo | -1.046 | in |
| ro | 4.496 | in |
| β | 0.946 | |
| Ixe at yield | 8.555 | in⁴ |
| Sxe | 1.186 | in³ |
Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.
Available strength (AISI S100-24)
| Action | Nominal | ASD, Rn/Ω | LRFD, φRn | Governed by |
|---|---|---|---|---|
| Strong-axis moment, flange braced (DSM) | 31.23 | 15.62 | 24.98 | §F3.2 · kip·in |
| Strong-axis moment, flange braced (EWM) | 37.59 | 22.51 | 33.83 | §F4 · kip·in |
| Shear, web without holes | 0.95 | 0.48 | 0.76 | §G2.1 · kip |
| Axial, 8 ft tall, braced at 4 ft (DSM) | 4.14 | 2.07 | 3.31 | §E4 · kip |
| Axial, 9 ft tall, braced at 4 ft (DSM) | 4.14 | 2.07 | 3.31 | §E4 · kip |
| Axial, 10 ft tall, braced at 4 ft (DSM) | 4.14 | 2.07 | 3.31 | §E4 · kip |
| Axial, 12 ft tall, braced at 4 ft (DSM) | 4.14 | 2.07 | 3.31 | §E4 · kip |
| Axial, 14 ft tall, braced at 4 ft (DSM) | 4.14 | 2.07 | 3.31 | §E4 · kip |
| Axial, 16 ft tall, braced at 4 ft (DSM) | 4.14 | 2.07 | 3.31 | §E4 · kip |
Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.
Elastic buckling
Finite strip results
| Py | 19.35 | kip |
| Pcrℓ at 8.7 | 0.79 | kip |
| Pcrd at 34.0 | 1.64 | kip |
| My | 60.31 | kip·in |
| Mcrℓ at 6.3 | 13.56 | kip·in |
| Mcrd at 28.7 | 28.35 | kip·in |
Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.
Quick answers
What does 1200S200-33 mean?
1200S200-33 is an SSMA designation: 12 in stud or joist, 2 in flange, 33 mil (0.0346 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0346 in.
What are the section properties of a 1200S200-33 stud?
Area 0.586 in², weight 2.00 lb/ft, Ix 10.965 in⁴, Sx 1.827 in³, rx 4.324 in, Iy 0.251 in⁴, ry 0.654 in, J 0.234 ×10⁻³ in⁴, Cw 7.117 in⁶, computed by ColdCalc with rounded corners.
What is the allowable moment of a 1200S200-33?
With the compression flange braced against lateral-torsional buckling and Fy = 33 ksi, AISI S100-24 gives a nominal strong-axis moment of 31.2 kip·in by the Direct Strength Method (governed by §F3.2): 15.6 kip·in allowable (ASD) or 25.0 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.
What are the local and distortional buckling loads of a 1200S200-33?
By finite strip analysis, local buckling in compression occurs at 0.79 kip (half-wavelength 8.7 in) and distortional buckling at 1.64 kip (34.0 in), against a squash load Py of 19.35 kip.
Other 12 in studs
Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation