1200S250-118 stud properties and strength

SSMA 12 in stud or joist, 2-1/2 in flange, 118 mil (0.1242 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1200S250-118 has an area of 2.152 in² and weighs 7.32 lb/ft. Its strong-axis moment of inertia is 40.727 in⁴ gross and 40.024 in⁴ effective at yield, and its effective section modulus is 6.555 in³. With the flange braced, its allowable moment is 186.8 kip·in (ASD), governed by distortional buckling (§F4).

12″2-1/2″0.625″ lipt = 0.1242″

Dimensions

Depth12in
Flange width2-1/2in
Lip length0.625in
Design thickness0.1242in
Minimum thickness0.1180in
Inside bend radius0.1863in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A2.152in²
Weight7.32lb/ft
Ix40.727in⁴
Sx6.788in³
rx4.350in
Iy1.308in⁴
Sy0.658in³
ry0.780in

Torsion and effective section

J11.065×10⁻³ in⁴
Cw35.439in⁶
xo-1.287in
ro4.603in
β0.922
Ixe at yield40.024in⁴
Sxe6.555in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)311.91186.77280.72§F4 · kip·in
Strong-axis moment, flange braced (EWM)311.82186.72280.64§F4 · kip·in
Shear, web without holes25.3415.1722.80§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)51.1528.4243.48§E4 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)51.1528.4243.48§E4 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)51.1528.4243.48§E4 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)51.1528.4243.48§E4 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)51.1528.4243.48§E4 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)51.1528.4243.48§E4 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (P/Py)Local0.32 at 12.0 inDistortional (by cFSM)0.36 at 21.5 in
Signature curve of the 1200S250-118 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.04.5101001000half-wavelength, in (log scale)load factor (M/My)Local (by cFSM)1.84 at 6.2 inDistortional1.49 at 14.8 in
Signature curve of the 1200S250-118 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py107.60kip
Pcrℓ at 12.034.09kip
Pcrd at 21.538.38kip
My339.39kip·in
Mcrℓ at 6.2624.50kip·in
Mcrd at 14.8505.71kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
34.09 kip at 12.0 in
Distortional
38.38 kip at 21.5 in
Buckled shapes of the 1200S250-118 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1200S250-118 mean?

1200S250-118 is an SSMA designation: 12 in stud or joist, 2-1/2 in flange, 118 mil (0.1242 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1242 in.

What are the section properties of a 1200S250-118 stud?

Area 2.152 in², weight 7.32 lb/ft, Ix 40.727 in⁴, Sx 6.788 in³, rx 4.350 in, Iy 1.308 in⁴, ry 0.780 in, J 11.065 ×10⁻³ in⁴, Cw 35.439 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1200S250-118?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 311.9 kip·in by the Direct Strength Method (governed by §F4): 186.8 kip·in allowable (ASD) or 280.7 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1200S250-118?

By finite strip analysis, local buckling in compression occurs at 34.09 kip (half-wavelength 12.0 in) and distortional buckling at 38.38 kip (21.5 in), against a squash load Py of 107.60 kip.

Other 12 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation