600S250-118 stud properties and strength

SSMA 6 in stud or joist, 2-1/2 in flange, 118 mil (0.1242 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 600S250-118 has an area of 1.407 in² and weighs 4.79 lb/ft. Its strong-axis moment of inertia is 7.714 in⁴ gross and 7.700 in⁴ effective at yield, and its effective section modulus is 2.563 in³. With the flange braced, its allowable moment is 75.7 kip·in (ASD), governed by distortional buckling (§F4).

6″2-1/2″0.625″ lipt = 0.1242″

Dimensions

Depth6in
Flange width2-1/2in
Lip length0.625in
Design thickness0.1242in
Minimum thickness0.1180in
Inside bend radius0.1863in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.407in²
Weight4.79lb/ft
Ix7.714in⁴
Sx2.571in³
rx2.342in
Iy1.076in⁴
Sy0.615in³
ry0.875in

Torsion and effective section

J7.234×10⁻³ in⁴
Cw7.393in⁶
xo-1.763in
ro3.059in
β0.668
Ixe at yield7.700in⁴
Sxe2.563in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)126.4075.69113.76§F4 · kip·in
Strong-axis moment, flange braced (EWM)126.3875.67113.74§F4 · kip·in
Shear, web without holes19.6311.7517.67§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)51.1028.3943.43§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)50.9628.3143.31§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)50.7228.1843.12§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)49.6027.5642.16§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)46.8626.0439.83§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)42.8623.8136.43§E2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.02.53.03.51101001000half-wavelength, in (log scale)load factor (P/Py)Local1.34 at 4.7 inDistortional1.40 at 14.3 in
Signature curve of the 600S250-118 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.04.55.05.56.06.57.07.58.08.59.09.510.010.511.011.512.012.513.013.514.01101001000half-wavelength, in (log scale)load factor (M/My)Local (by cFSM)6.16 at 3.2 inDistortional2.66 at 13.2 in
Signature curve of the 600S250-118 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py70.34kip
Pcrℓ at 4.793.98kip
Pcrd at 14.398.18kip
My128.57kip·in
Mcrℓ at 3.2791.45kip·in
Mcrd at 13.2341.44kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
93.98 kip at 4.7 in
Distortional
98.18 kip at 14.3 in
Buckled shapes of the 600S250-118 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 600S250-118 mean?

600S250-118 is an SSMA designation: 6 in stud or joist, 2-1/2 in flange, 118 mil (0.1242 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1242 in.

What are the section properties of a 600S250-118 stud?

Area 1.407 in², weight 4.79 lb/ft, Ix 7.714 in⁴, Sx 2.571 in³, rx 2.342 in, Iy 1.076 in⁴, ry 0.875 in, J 7.234 ×10⁻³ in⁴, Cw 7.393 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 600S250-118?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 126.4 kip·in by the Direct Strength Method (governed by §F4): 75.7 kip·in allowable (ASD) or 113.8 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 600S250-118?

By finite strip analysis, local buckling in compression occurs at 93.98 kip (half-wavelength 4.7 in) and distortional buckling at 98.18 kip (14.3 in), against a squash load Py of 70.34 kip.

Other 6 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation