600S162-30 stud properties and strength

SSMA 6 in stud or joist, 1-5/8 in flange, 30 mil (0.0312 in), Grade 33 (ASTM A1003 ST33H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 600S162-30 has an area of 0.311 in² and weighs 1.06 lb/ft. Its strong-axis moment of inertia is 1.621 in⁴ gross and 1.533 in⁴ effective at yield, and its effective section modulus is 0.492 in³. With the flange braced, its allowable moment is 8.1 kip·in (ASD), governed by local buckling (§F3).

6″1-5/8″0.5″ lipt = 0.0312″

Dimensions

Depth6in
Flange width1-5/8in
Lip length0.5in
Design thickness0.0312in
Minimum thickness0.0296in
Inside bend radius0.0782in
Yield stress Fy33ksi
Tensile strength Fu45ksi

Gross properties

Area A0.311in²
Weight1.06lb/ft
Ix1.621in⁴
Sx0.540in³
rx2.284in
Iy0.105in⁴
Sy0.087in³
ry0.583in

Torsion and effective section

J0.101×10⁻³ in⁴
Cw0.752in⁶
xo-1.072in
ro2.589in
β0.829
Ixe at yield1.533in⁴
Sxe0.492in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)13.558.1112.19§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)14.578.7313.11§F4 · kip·in
Shear, web without holes1.150.691.04§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)3.411.892.90§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)3.411.892.90§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)3.411.892.90§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)3.411.892.90§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)3.411.892.90§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)3.341.862.84§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.13 at 4.5 inDistortional (by cFSM)0.34 at 22.2 in
Signature curve of the 600S162-30 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.51101001000half-wavelength, in (log scale)load factor (M/My)Local0.70 at 3.2 inDistortional1.09 at 18.7 in
Signature curve of the 600S162-30 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py10.26kip
Pcrℓ at 4.51.32kip
Pcrd at 22.23.53kip
My17.84kip·in
Mcrℓ at 3.212.43kip·in
Mcrd at 18.719.53kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
1.32 kip at 4.5 in
Distortional
3.53 kip at 22.2 in
Buckled shapes of the 600S162-30 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 600S162-30 mean?

600S162-30 is an SSMA designation: 6 in stud or joist, 1-5/8 in flange, 30 mil (0.0312 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0312 in.

What are the section properties of a 600S162-30 stud?

Area 0.311 in², weight 1.06 lb/ft, Ix 1.621 in⁴, Sx 0.540 in³, rx 2.284 in, Iy 0.105 in⁴, ry 0.583 in, J 0.101 ×10⁻³ in⁴, Cw 0.752 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 600S162-30?

With the compression flange braced against lateral-torsional buckling and Fy = 33 ksi, AISI S100-24 gives a nominal strong-axis moment of 13.5 kip·in by the Direct Strength Method (governed by §F3.2): 8.1 kip·in allowable (ASD) or 12.2 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 600S162-30?

By finite strip analysis, local buckling in compression occurs at 1.32 kip (half-wavelength 4.5 in) and distortional buckling at 3.53 kip (22.2 in), against a squash load Py of 10.26 kip.

Other 6 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation