162S162-33 stud properties and strength

SSMA 1-5/8 in stud or joist, 1-5/8 in flange, 33 mil (0.0346 in), Grade 33 (ASTM A1003 ST33H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 162S162-33 has an area of 0.193 in² and weighs 0.66 lb/ft. Its strong-axis moment of inertia is 0.088 in⁴ gross and 0.086 in⁴ effective at yield, and its effective section modulus is 0.104 in³. With the flange braced, its allowable moment is 2.0 kip·in (ASD), governed by local buckling (§F3).

1-5/8″1-5/8″0.5″ lipt = 0.0346″

Dimensions

Depth1-5/8in
Flange width1-5/8in
Lip length0.5in
Design thickness0.0346in
Minimum thickness0.0329in
Inside bend radius0.0765in
Yield stress Fy33ksi
Tensile strength Fu45ksi

Gross properties

Area A0.193in²
Weight0.66lb/ft
Ix0.088in⁴
Sx0.109in³
rx0.677in
Iy0.074in⁴
Sy0.082in³
ry0.619in

Torsion and effective section

J0.077×10⁻³ in⁴
Cw0.070in⁶
xo-1.628in
ro1.869in
β0.241
Ixe at yield0.086in⁴
Sxe0.104in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)3.362.013.03§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)3.412.043.07§F4 · kip·in
Shear, web without holes0.960.580.86§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)1.710.951.45§E2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)1.540.861.31§E2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)1.360.761.16§E2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)1.030.570.87§E2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)0.780.430.66§E2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)0.600.340.51§E2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.02.53.03.54.01101001000half-wavelength, in (log scale)load factor (P/Py)Local1.59 at 1.6 inDistortional1.66 at 15.9 in
Signature curve of the 162S162-33 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.04.55.05.56.01101001000half-wavelength, in (log scale)load factor (M/My)Local2.03 at 1.4 inDistortional (by cFSM)2.65 at 13.5 in
Signature curve of the 162S162-33 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py6.37kip
Pcrℓ at 1.610.14kip
Pcrd at 15.910.56kip
My3.59kip·in
Mcrℓ at 1.47.30kip·in
Mcrd at 13.59.54kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
10.14 kip at 1.6 in
Distortional
10.56 kip at 15.9 in
Buckled shapes of the 162S162-33 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 162S162-33 mean?

162S162-33 is an SSMA designation: 1-5/8 in stud or joist, 1-5/8 in flange, 33 mil (0.0346 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0346 in.

What are the section properties of a 162S162-33 stud?

Area 0.193 in², weight 0.66 lb/ft, Ix 0.088 in⁴, Sx 0.109 in³, rx 0.677 in, Iy 0.074 in⁴, ry 0.619 in, J 0.077 ×10⁻³ in⁴, Cw 0.070 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 162S162-33?

With the compression flange braced against lateral-torsional buckling and Fy = 33 ksi, AISI S100-24 gives a nominal strong-axis moment of 3.4 kip·in by the Direct Strength Method (governed by §F3.2): 2.0 kip·in allowable (ASD) or 3.0 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 162S162-33?

By finite strip analysis, local buckling in compression occurs at 10.14 kip (half-wavelength 1.6 in) and distortional buckling at 10.56 kip (15.9 in), against a squash load Py of 6.37 kip.

Other 1-5/8 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation