162S137-68 stud properties and strength

SSMA 1-5/8 in stud or joist, 1-3/8 in flange, 68 mil (0.0713 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 162S137-68 has an area of 0.328 in² and weighs 1.11 lb/ft. Its strong-axis moment of inertia is 0.142 in⁴ gross and 0.142 in⁴ effective at yield, and its effective section modulus is 0.174 in³. With the flange braced, its allowable moment is 5.4 kip·in (ASD), governed by distortional buckling (§F4).

1-5/8″1-3/8″0.375″ lipt = 0.0713″

Dimensions

Depth1-5/8in
Flange width1-3/8in
Lip length0.375in
Design thickness0.0713in
Minimum thickness0.0677in
Inside bend radius0.1070in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A0.328in²
Weight1.11lb/ft
Ix0.142in⁴
Sx0.174in³
rx0.657in
Iy0.081in⁴
Sy0.100in³
ry0.497in

Torsion and effective section

J0.555×10⁻³ in⁴
Cw0.055in⁶
xo-1.235in
ro1.485in
β0.308
Ixe at yield0.142in⁴
Sxe0.174in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)9.005.398.10§F4 · kip·in
Strong-axis moment, flange braced (EWM)8.725.227.84§F2.1 · kip·in
Shear, web without holes2.711.622.44§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)3.131.742.66§E2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)2.711.502.30§E2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)2.311.281.96§E2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)1.680.931.43§E2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)1.260.701.07§E2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)0.970.540.83§E2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.02.53.03.54.04.55.05.56.06.57.07.58.08.59.09.510.010.511.011.512.012.51101001000half-wavelength, in (log scale)load factor (P/Py)Local5.51 at 1.5 inDistortional2.71 at 7.4 in
Signature curve of the 162S137-68 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.04.55.05.56.06.57.07.58.08.59.09.510.010.511.011.512.012.513.013.514.014.515.015.516.016.517.017.518.018.519.01101001000half-wavelength, in (log scale)load factor (M/My)Local8.57 at 1.3 inDistortional4.08 at 7.4 in
Signature curve of the 162S137-68 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py16.38kip
Pcrℓ at 1.590.25kip
Pcrd at 7.444.32kip
My8.72kip·in
Mcrℓ at 1.374.67kip·in
Mcrd at 7.435.60kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
90.25 kip at 1.5 in
Distortional
44.32 kip at 7.4 in
Buckled shapes of the 162S137-68 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 162S137-68 mean?

162S137-68 is an SSMA designation: 1-5/8 in stud or joist, 1-3/8 in flange, 68 mil (0.0713 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0713 in.

What are the section properties of a 162S137-68 stud?

Area 0.328 in², weight 1.11 lb/ft, Ix 0.142 in⁴, Sx 0.174 in³, rx 0.657 in, Iy 0.081 in⁴, ry 0.497 in, J 0.555 ×10⁻³ in⁴, Cw 0.055 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 162S137-68?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 9.0 kip·in by the Direct Strength Method (governed by §F4): 5.4 kip·in allowable (ASD) or 8.1 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 162S137-68?

By finite strip analysis, local buckling in compression occurs at 90.25 kip (half-wavelength 1.5 in) and distortional buckling at 44.32 kip (7.4 in), against a squash load Py of 16.38 kip.

Other 1-5/8 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation