1400T200-33 track properties and strength
SSMA 14 in track, 2 in flange, 33 mil (0.0346 in), Grade 33 (ASTM A1003 ST33H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.
The 1400T200-33 has an area of 0.620 in² and weighs 2.11 lb/ft. Its strong-axis moment of inertia is 14.589 in⁴ gross and 7.434 in⁴ effective at yield, and its effective section modulus is 0.757 in³. With the flange braced, its allowable moment is 14.2 kip·in (ASD), governed by local buckling (§F3).
Dimensions
| Depth (inside) | 14 | in |
| Flange width | 2 | in |
| Design thickness | 0.0346 | in |
| Minimum thickness | 0.0329 | in |
| Inside bend radius | 0.0765 | in |
| Yield stress Fy | 33 | ksi |
| Tensile strength Fu | 45 | ksi |
Gross properties
| Area A | 0.620 | in² |
| Weight | 2.11 | lb/ft |
| Ix | 14.589 | in⁴ |
| Sx | 2.074 | in³ |
| rx | 4.851 | in |
| Iy | 0.150 | in⁴ |
| Sy | 0.085 | in³ |
| ry | 0.492 | in |
Torsion and effective section
| J | 0.247 | ×10⁻³ in⁴ |
| Cw | 5.772 | in⁶ |
| xo | -0.678 | in |
| ro | 4.923 | in |
| β | 0.981 | |
| Ixe at yield | 7.434 | in⁴ |
| Sxe | 0.757 | in³ |
Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.
Available strength (AISI S100-24)
| Action | Nominal | ASD, Rn/Ω | LRFD, φRn | Governed by |
|---|---|---|---|---|
| Strong-axis moment, flange braced (DSM) | 28.41 | 14.20 | 22.73 | §F3.2 · kip·in |
| Strong-axis moment, flange braced (EWM) | 24.98 | 14.96 | 22.48 | §F3.1 · kip·in |
| Shear, web without holes | 0.83 | 0.42 | 0.66 | §G2.1 · kip |
| Axial, 8 ft tall, braced at 4 ft (DSM) | 3.61 | 1.80 | 2.88 | §E3.2 · kip |
| Axial, 9 ft tall, braced at 4 ft (DSM) | 3.61 | 1.80 | 2.88 | §E3.2 · kip |
| Axial, 10 ft tall, braced at 4 ft (DSM) | 3.61 | 1.80 | 2.88 | §E3.2 · kip |
| Axial, 12 ft tall, braced at 4 ft (DSM) | 3.61 | 1.80 | 2.88 | §E3.2 · kip |
| Axial, 14 ft tall, braced at 4 ft (DSM) | 3.61 | 1.80 | 2.88 | §E3.2 · kip |
| Axial, 16 ft tall, braced at 4 ft (DSM) | 3.61 | 1.80 | 2.88 | §E3.2 · kip |
Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.
Elastic buckling
Finite strip results
| Py | 20.46 | kip |
| Pcrℓ at 13.8 | 0.46 | kip |
| My | 68.44 | kip·in |
| Mcrℓ at 9.6 | 8.00 | kip·in |
Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.
Quick answers
What does 1400T200-33 mean?
1400T200-33 is an SSMA designation: 14 in track, 2 in flange, 33 mil (0.0346 in). The first number is the inside depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0346 in.
What are the section properties of a 1400T200-33 track?
Area 0.620 in², weight 2.11 lb/ft, Ix 14.589 in⁴, Sx 2.074 in³, rx 4.851 in, Iy 0.150 in⁴, ry 0.492 in, J 0.247 ×10⁻³ in⁴, Cw 5.772 in⁶, computed by ColdCalc with rounded corners.
What is the allowable moment of a 1400T200-33?
With the compression flange braced against lateral-torsional buckling and Fy = 33 ksi, AISI S100-24 gives a nominal strong-axis moment of 28.4 kip·in by the Direct Strength Method (governed by §F3.2): 14.2 kip·in allowable (ASD) or 22.7 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.
What are the local and distortional buckling loads of a 1400T200-33?
By finite strip analysis, local buckling in compression occurs at 0.46 kip (half-wavelength 13.8 in), against a squash load Py of 20.46 kip.
Other 14 in tracks
Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation