1400T125-97 track properties and strength
SSMA 14 in track, 1-1/4 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.
The 1400T125-97 has an area of 1.660 in² and weighs 5.65 lb/ft. Its strong-axis moment of inertia is 35.000 in⁴ gross and 31.521 in⁴ effective at yield, and its effective section modulus is 4.081 in³. With the flange braced, its allowable moment is 127.3 kip·in (ASD), governed by local buckling (§F3).
Dimensions
| Depth (inside) | 14 | in |
| Flange width | 1-1/4 | in |
| Design thickness | 0.1017 | in |
| Minimum thickness | 0.0966 | in |
| Inside bend radius | 0.1526 | in |
| Yield stress Fy | 50 | ksi |
| Tensile strength Fu | 65 | ksi |
Gross properties
| Area A | 1.660 | in² |
| Weight | 5.65 | lb/ft |
| Ix | 35.000 | in⁴ |
| Sx | 4.928 | in³ |
| rx | 4.591 | in |
| Iy | 0.104 | in⁴ |
| Sy | 0.094 | in³ |
| ry | 0.250 | in |
Torsion and effective section
| J | 5.724 | ×10⁻³ in⁴ |
| Cw | 4.267 | in⁶ |
| xo | -0.296 | in |
| ro | 4.608 | in |
| β | 0.996 | |
| Ixe at yield | 31.521 | in⁴ |
| Sxe | 4.081 | in³ |
Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.
Available strength (AISI S100-24)
| Action | Nominal | ASD, Rn/Ω | LRFD, φRn | Governed by |
|---|---|---|---|---|
| Strong-axis moment, flange braced (DSM) | 212.67 | 127.35 | 191.40 | §F3.2 · kip·in |
| Strong-axis moment, flange braced (EWM) | 204.06 | 122.19 | 183.65 | §F3.1 · kip·in |
| Shear, web without holes | 15.78 | 9.45 | 14.20 | §G2.1 · kip |
| Axial, 8 ft tall, braced at 4 ft (DSM) | 9.40 | 5.22 | 7.99 | §E3.2 · kip |
| Axial, 9 ft tall, braced at 4 ft (DSM) | 9.40 | 5.22 | 7.99 | §E3.2 · kip |
| Axial, 10 ft tall, braced at 4 ft (DSM) | 9.40 | 5.22 | 7.99 | §E3.2 · kip |
| Axial, 12 ft tall, braced at 4 ft (DSM) | 9.40 | 5.22 | 7.99 | §E3.2 · kip |
| Axial, 14 ft tall, braced at 4 ft (DSM) | 9.40 | 5.22 | 7.99 | §E3.2 · kip |
| Axial, 16 ft tall, braced at 4 ft (DSM) | 9.40 | 5.22 | 7.99 | §E3.2 · kip |
Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.
Elastic buckling
Finite strip results
| Py | 83.01 | kip |
| Pcrℓ at 14.7 | 9.86 | kip |
| My | 246.42 | kip·in |
| Mcrℓ at 10.0 | 172.17 | kip·in |
Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.
Quick answers
What does 1400T125-97 mean?
1400T125-97 is an SSMA designation: 14 in track, 1-1/4 in flange, 97 mil (0.1017 in). The first number is the inside depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.
What are the section properties of a 1400T125-97 track?
Area 1.660 in², weight 5.65 lb/ft, Ix 35.000 in⁴, Sx 4.928 in³, rx 4.591 in, Iy 0.104 in⁴, ry 0.250 in, J 5.724 ×10⁻³ in⁴, Cw 4.267 in⁶, computed by ColdCalc with rounded corners.
What is the allowable moment of a 1400T125-97?
With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 212.7 kip·in by the Direct Strength Method (governed by §F3.2): 127.3 kip·in allowable (ASD) or 191.4 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.
What are the local and distortional buckling loads of a 1400T125-97?
By finite strip analysis, local buckling in compression occurs at 9.86 kip (half-wavelength 14.7 in), against a squash load Py of 83.01 kip.
Other 14 in tracks
Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation