1000S200-68 stud properties and strength

SSMA 10 in stud or joist, 2 in flange, 68 mil (0.0713 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1000S200-68 has an area of 1.050 in² and weighs 3.57 lb/ft. Its strong-axis moment of inertia is 13.994 in⁴ gross and 13.000 in⁴ effective at yield, and its effective section modulus is 2.424 in³. With the flange braced, its allowable moment is 69.0 kip·in (ASD), governed by distortional buckling (§F4).

10″2″0.625″ lipt = 0.0713″

Dimensions

Depth10in
Flange width2in
Lip length0.625in
Design thickness0.0713in
Minimum thickness0.0677in
Inside bend radius0.1070in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.050in²
Weight3.57lb/ft
Ix13.994in⁴
Sx2.799in³
rx3.652in
Iy0.460in⁴
Sy0.292in³
ry0.662in

Torsion and effective section

J1.779×10⁻³ in⁴
Cw8.937in⁶
xo-1.111in
ro3.874in
β0.918
Ixe at yield13.000in⁴
Sxe2.424in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)115.2168.99103.69§F4 · kip·in
Strong-axis moment, flange braced (EWM)115.1868.97103.66§F4 · kip·in
Shear, web without holes7.744.646.97§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)18.4410.2415.67§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)18.4410.2415.67§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)18.4410.2415.67§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)18.4410.2415.67§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)18.4410.2415.67§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)18.4410.2415.67§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.16 at 7.6 inDistortional (by cFSM)0.23 at 22.6 in
Signature curve of the 1000S200-68 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads; the distortional mode has no distinct minimum here, so it was identified by its modal participation (cFSM). The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.51101001000half-wavelength, in (log scale)load factor (M/My)Local0.90 at 5.4 inDistortional1.02 at 16.6 in
Signature curve of the 1000S200-68 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py52.48kip
Pcrℓ at 7.68.47kip
Pcrd at 22.611.93kip
My139.94kip·in
Mcrℓ at 5.4125.53kip·in
Mcrd at 16.6142.29kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
8.47 kip at 7.6 in
Distortional
11.93 kip at 22.6 in
Buckled shapes of the 1000S200-68 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1000S200-68 mean?

1000S200-68 is an SSMA designation: 10 in stud or joist, 2 in flange, 68 mil (0.0713 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0713 in.

What are the section properties of a 1000S200-68 stud?

Area 1.050 in², weight 3.57 lb/ft, Ix 13.994 in⁴, Sx 2.799 in³, rx 3.652 in, Iy 0.460 in⁴, ry 0.662 in, J 1.779 ×10⁻³ in⁴, Cw 8.937 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1000S200-68?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 115.2 kip·in by the Direct Strength Method (governed by §F4): 69.0 kip·in allowable (ASD) or 103.7 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1000S200-68?

By finite strip analysis, local buckling in compression occurs at 8.47 kip (half-wavelength 7.6 in) and distortional buckling at 11.93 kip (22.6 in), against a squash load Py of 52.48 kip.

Other 10 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation