Inputs
Moment gradient factorCb
Credit for moment that varies along the unbraced length; 1.0 is always safe.
Lateral-torsional buckling is worst when the moment is constant between braces. When it varies, the member is stronger, and Cb > 1 reflects that. Use 1.0 if unsure.
- Typical values
- 1.0 (conservative) to about 1.3 for a uniformly loaded segment.
- Specification
- AISI S100-24 Appendix 2 §2.3.1.2