600T125-97 track properties and strength

SSMA 6 in track, 1-1/4 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 600T125-97 has an area of 0.847 in² and weighs 2.88 lb/ft. Its strong-axis moment of inertia is 4.027 in⁴ gross and 4.027 in⁴ effective at yield, and its effective section modulus is 1.298 in³. With the flange braced, its allowable moment is 42.4 kip·in (ASD), governed by local buckling (§F3).

6-1/4″1-1/4″t = 0.1017″

Dimensions

Depth (inside)6in
Flange width1-1/4in
Design thickness0.1017in
Minimum thickness0.0966in
Inside bend radius0.1526in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A0.847in²
Weight2.88lb/ft
Ix4.027in⁴
Sx1.298in³
rx2.181in
Iy0.091in⁴
Sy0.089in³
ry0.329in

Torsion and effective section

J2.919×10⁻³ in⁴
Cw0.618in⁶
xo-0.510in
ro2.263in
β0.949
Ixe at yield4.027in⁴
Sxe1.298in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)70.8942.4563.80§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)64.9138.8758.42§F2.1 · kip·in
Shear, web without holes15.159.0713.63§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)10.145.638.62§E2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)10.145.638.62§E2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)10.145.638.62§E2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)10.145.638.62§E2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)10.145.638.62§E2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)10.145.638.62§E2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.67 at 6.2 in
Signature curve of the 600T125-97 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.54.04.55.05.56.06.51101001000half-wavelength, in (log scale)load factor (M/My)Local2.82 at 4.2 in
Signature curve of the 600T125-97 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py42.33kip
Pcrℓ at 6.228.45kip
My64.91kip·in
Mcrℓ at 4.2183.27kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
28.45 kip at 6.2 in
Buckled shapes of the 600T125-97 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 600T125-97 mean?

600T125-97 is an SSMA designation: 6 in track, 1-1/4 in flange, 97 mil (0.1017 in). The first number is the inside depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.

What are the section properties of a 600T125-97 track?

Area 0.847 in², weight 2.88 lb/ft, Ix 4.027 in⁴, Sx 1.298 in³, rx 2.181 in, Iy 0.091 in⁴, ry 0.329 in, J 2.919 ×10⁻³ in⁴, Cw 0.618 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 600T125-97?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 70.9 kip·in by the Direct Strength Method (governed by §F3.2): 42.4 kip·in allowable (ASD) or 63.8 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 600T125-97?

By finite strip analysis, local buckling in compression occurs at 28.45 kip (half-wavelength 6.2 in), against a squash load Py of 42.33 kip.

Other 6 in tracks

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation