400S200-33 stud properties and strength

SSMA 4 in stud or joist, 2 in flange, 33 mil (0.0346 in), Grade 33 (ASTM A1003 ST33H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 400S200-33 has an area of 0.310 in² and weighs 1.05 lb/ft. Its strong-axis moment of inertia is 0.812 in⁴ gross and 0.761 in⁴ effective at yield, and its effective section modulus is 0.365 in³. With the flange braced, its allowable moment is 6.8 kip·in (ASD), governed by local buckling (§F3).

4″2″0.625″ lipt = 0.0346″

Dimensions

Depth4in
Flange width2in
Lip length0.625in
Design thickness0.0346in
Minimum thickness0.0329in
Inside bend radius0.0765in
Yield stress Fy33ksi
Tensile strength Fu45ksi

Gross properties

Area A0.310in²
Weight1.05lb/ft
Ix0.812in⁴
Sx0.406in³
rx1.619in
Iy0.183in⁴
Sy0.141in³
ry0.769in

Torsion and effective section

J0.124×10⁻³ in⁴
Cw0.673in⁶
xo-1.687in
ro2.462in
β0.530
Ixe at yield0.761in⁴
Sxe0.365in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)11.416.8310.27§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)11.506.8910.35§F4 · kip·in
Shear, web without holes1.600.961.44§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)4.922.734.18§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)4.892.724.16§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)4.842.694.12§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)4.652.583.95§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)4.322.403.67§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)3.912.173.33§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.34 at 3.1 inDistortional0.87 at 25.0 in
Signature curve of the 400S200-33 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.03.51101001000half-wavelength, in (log scale)load factor (M/My)Local1.20 at 2.0 inDistortional1.51 at 22.7 in
Signature curve of the 400S200-33 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py10.22kip
Pcrℓ at 3.13.46kip
Pcrd at 25.08.91kip
My13.40kip·in
Mcrℓ at 2.016.12kip·in
Mcrd at 22.720.27kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
3.46 kip at 3.1 in
Distortional
8.91 kip at 25.0 in
Buckled shapes of the 400S200-33 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 400S200-33 mean?

400S200-33 is an SSMA designation: 4 in stud or joist, 2 in flange, 33 mil (0.0346 in). The first number is the depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0346 in.

What are the section properties of a 400S200-33 stud?

Area 0.310 in², weight 1.05 lb/ft, Ix 0.812 in⁴, Sx 0.406 in³, rx 1.619 in, Iy 0.183 in⁴, ry 0.769 in, J 0.124 ×10⁻³ in⁴, Cw 0.673 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 400S200-33?

With the compression flange braced against lateral-torsional buckling and Fy = 33 ksi, AISI S100-24 gives a nominal strong-axis moment of 11.4 kip·in by the Direct Strength Method (governed by §F3.2): 6.8 kip·in allowable (ASD) or 10.3 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 400S200-33?

By finite strip analysis, local buckling in compression occurs at 3.46 kip (half-wavelength 3.1 in) and distortional buckling at 8.91 kip (25.0 in), against a squash load Py of 10.22 kip.

Other 4 in studs

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation