162T200-30 track properties and strength

SSMA 1-5/8 in track, 2 in flange, 30 mil (0.0312 in), Grade 33 (ASTM A1003 ST33H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 162T200-30 has an area of 0.173 in² and weighs 0.59 lb/ft. Its strong-axis moment of inertia is 0.095 in⁴ gross and 0.057 in⁴ effective at yield, and its effective section modulus is 0.051 in³. With the flange braced, its allowable moment is 0.8 kip·in (ASD), governed by local buckling (§F3).

1-5/8″2″t = 0.0312″

Dimensions

Depth (inside)1-5/8in
Flange width2in
Design thickness0.0312in
Minimum thickness0.0296in
Inside bend radius0.0782in
Yield stress Fy33ksi
Tensile strength Fu45ksi

Gross properties

Area A0.173in²
Weight0.59lb/ft
Ix0.095in⁴
Sx0.113in³
rx0.741in
Iy0.075in⁴
Sy0.059in³
ry0.659in

Torsion and effective section

J0.056×10⁻³ in⁴
Cw0.037in⁶
xo-1.594in
ro1.877in
β0.279
Ixe at yield0.057in⁴
Sxe0.051in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)1.630.811.30§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)1.691.011.53§F3.1 · kip·in
Shear, web without holes0.910.450.73§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)0.950.480.76§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)0.940.470.75§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)0.910.460.73§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)0.840.420.67§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)0.720.360.58§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)0.600.300.48§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (P/Py)Local0.18 at 4.2 in
Signature curve of the 162T200-30 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.01101001000half-wavelength, in (log scale)load factor (M/My)Local0.21 at 3.9 in
Signature curve of the 162T200-30 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py5.71kip
Pcrℓ at 4.21.05kip
My3.71kip·in
Mcrℓ at 3.90.77kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
1.05 kip at 4.2 in
Buckled shapes of the 162T200-30 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 162T200-30 mean?

162T200-30 is an SSMA designation: 1-5/8 in track, 2 in flange, 30 mil (0.0312 in). The first number is the inside depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0312 in.

What are the section properties of a 162T200-30 track?

Area 0.173 in², weight 0.59 lb/ft, Ix 0.095 in⁴, Sx 0.113 in³, rx 0.741 in, Iy 0.075 in⁴, ry 0.659 in, J 0.056 ×10⁻³ in⁴, Cw 0.037 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 162T200-30?

With the compression flange braced against lateral-torsional buckling and Fy = 33 ksi, AISI S100-24 gives a nominal strong-axis moment of 1.6 kip·in by the Direct Strength Method (governed by §F3.2): 0.8 kip·in allowable (ASD) or 1.3 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 162T200-30?

By finite strip analysis, local buckling in compression occurs at 1.05 kip (half-wavelength 4.2 in), against a squash load Py of 5.71 kip.

Other 1-5/8 in tracks

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation