1200T200-54 track properties and strength

SSMA 12 in track, 2 in flange, 54 mil (0.0566 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1200T200-54 has an area of 0.900 in² and weighs 3.06 lb/ft. Its strong-axis moment of inertia is 16.176 in⁴ gross and 10.403 in⁴ effective at yield, and its effective section modulus is 1.341 in³. With the flange braced, its allowable moment is 44.9 kip·in (ASD), governed by local buckling (§F3).

12-1/8″2″t = 0.0566″

Dimensions

Depth (inside)12in
Flange width2in
Design thickness0.0566in
Minimum thickness0.0538in
Inside bend radius0.0849in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A0.900in²
Weight3.06lb/ft
Ix16.176in⁴
Sx2.671in³
rx4.239in
Iy0.235in⁴
Sy0.136in³
ry0.511in

Torsion and effective section

J0.961×10⁻³ in⁴
Cw6.547in⁶
xo-0.739in
ro4.333in
β0.971
Ixe at yield10.403in⁴
Sxe1.341in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)74.9144.8667.42§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)67.0340.1460.33§F3.1 · kip·in
Shear, web without holes3.861.933.09§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)8.854.927.52§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)8.854.927.52§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)8.854.927.52§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)8.854.927.52§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)8.854.927.52§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)8.854.927.52§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (P/Py)Local0.05 at 11.9 in
Signature curve of the 1200T200-54 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (M/My)Local0.26 at 8.3 in
Signature curve of the 1200T200-54 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py45.01kip
Pcrℓ at 11.92.41kip
My133.54kip·in
Mcrℓ at 8.334.77kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
2.41 kip at 11.9 in
Buckled shapes of the 1200T200-54 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1200T200-54 mean?

1200T200-54 is an SSMA designation: 12 in track, 2 in flange, 54 mil (0.0566 in). The first number is the inside depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.0566 in.

What are the section properties of a 1200T200-54 track?

Area 0.900 in², weight 3.06 lb/ft, Ix 16.176 in⁴, Sx 2.671 in³, rx 4.239 in, Iy 0.235 in⁴, ry 0.511 in, J 0.961 ×10⁻³ in⁴, Cw 6.547 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1200T200-54?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 74.9 kip·in by the Direct Strength Method (governed by §F3.2): 44.9 kip·in allowable (ASD) or 67.4 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1200T200-54?

By finite strip analysis, local buckling in compression occurs at 2.41 kip (half-wavelength 11.9 in), against a squash load Py of 45.01 kip.

Other 12 in tracks

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation