1000T150-97 track properties and strength

SSMA 10 in track, 1-1/2 in flange, 97 mil (0.1017 in), Grade 50 (ASTM A1003 ST50H). Gross and effective properties, finite strip buckling loads and available strengths to AISI S100-24, computed by the ColdCalc engine.

The 1000T150-97 has an area of 1.304 in² and weighs 4.44 lb/ft. Its strong-axis moment of inertia is 15.797 in⁴ gross and 15.061 in⁴ effective at yield, and its effective section modulus is 2.851 in³. With the flange braced, its allowable moment is 90.1 kip·in (ASD), governed by local buckling (§F3).

10-1/4″1-1/2″t = 0.1017″

Dimensions

Depth (inside)10in
Flange width1-1/2in
Design thickness0.1017in
Minimum thickness0.0966in
Inside bend radius0.1526in
Yield stress Fy50ksi
Tensile strength Fu65ksi

Gross properties

Area A1.304in²
Weight4.44lb/ft
Ix15.797in⁴
Sx3.096in³
rx3.480in
Iy0.171in⁴
Sy0.133in³
ry0.362in

Torsion and effective section

J4.497×10⁻³ in⁴
Cw3.355in⁶
xo-0.508in
ro3.536in
β0.979
Ixe at yield15.061in⁴
Sxe2.851in³

Effective properties: AISI S100-24 Appendix 1, strong-axis bending with the extreme fiber at Fy.

Available strength (AISI S100-24)

ActionNominalASD, Rn/ΩLRFD, φRnGoverned by
Strong-axis moment, flange braced (DSM)150.5490.14135.49§F3.2 · kip·in
Strong-axis moment, flange braced (EWM)142.5685.36128.30§F3.1 · kip·in
Shear, web without holes16.9710.1615.27§G2.1 · kip
Axial, 8 ft tall, braced at 4 ft (DSM)15.378.5413.07§E3.2 · kip
Axial, 9 ft tall, braced at 4 ft (DSM)15.378.5413.07§E3.2 · kip
Axial, 10 ft tall, braced at 4 ft (DSM)15.378.5413.07§E3.2 · kip
Axial, 12 ft tall, braced at 4 ft (DSM)15.378.5413.07§E3.2 · kip
Axial, 14 ft tall, braced at 4 ft (DSM)15.378.5413.07§E3.2 · kip
Axial, 16 ft tall, braced at 4 ft (DSM)15.378.5413.07§E3.2 · kip

Axial: pinned ends, weak-axis and torsional bracing every 48 in, concentric load. No holes. Bending and axial load together, unbraced flanges, web crippling and deflection depend on the member: check them in the calculator.

Elastic buckling

0.00.51.01.52.0101001000half-wavelength, in (log scale)load factor (P/Py)Local0.24 at 10.2 in
Signature curve of the 1000T150-97 in pure compression: the elastic buckling load, as a multiple of the yield load Py, at each buckle half-wavelength. The marked points are the local (Pcrℓ) and distortional (Pcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.
0.00.51.01.52.02.53.0101001000half-wavelength, in (log scale)load factor (M/My)Local1.28 at 7.0 in
Signature curve of the 1000T150-97 in strong-axis bending: the elastic buckling load, as a multiple of the yield moment My, at each buckle half-wavelength. The marked points are the local (Mcrℓ) and distortional (Mcrd) buckling loads, each a minimum of the curve. The falling branch on the right is global buckling. Finite strip analysis by ColdCalc, simply supported ends, E = 29,500 ksi.

Finite strip results

Py65.22kip
Pcrℓ at 10.215.84kip
My154.82kip·in
Mcrℓ at 7.0198.08kip·in

Signature curve minima, labelled by modal participation (cFSM). Half-wavelengths in inches.

Local
15.84 kip at 10.2 in
Buckled shapes of the 1000T150-97 in compression, from the same finite strip analysis. Local buckling ripples the flat walls with the corners staying put; distortional buckling rotates a flange and its lip about the web–flange corner.

Quick answers

What does 1000T150-97 mean?

1000T150-97 is an SSMA designation: 10 in track, 1-1/2 in flange, 97 mil (0.1017 in). The first number is the inside depth in hundredths of an inch, the letter is the style (S for a stud or joist with lips, T for track), the next number is the flange width in hundredths of an inch, and the last is the minimum thickness in mils. The design thickness is 0.1017 in.

What are the section properties of a 1000T150-97 track?

Area 1.304 in², weight 4.44 lb/ft, Ix 15.797 in⁴, Sx 3.096 in³, rx 3.480 in, Iy 0.171 in⁴, ry 0.362 in, J 4.497 ×10⁻³ in⁴, Cw 3.355 in⁶, computed by ColdCalc with rounded corners.

What is the allowable moment of a 1000T150-97?

With the compression flange braced against lateral-torsional buckling and Fy = 50 ksi, AISI S100-24 gives a nominal strong-axis moment of 150.5 kip·in by the Direct Strength Method (governed by §F3.2): 90.1 kip·in allowable (ASD) or 135.5 kip·in design strength (LRFD). Unbraced lengths, holes and combined loads reduce it.

What are the local and distortional buckling loads of a 1000T150-97?

By finite strip analysis, local buckling in compression occurs at 15.84 kip (half-wavelength 10.2 in), against a squash load Py of 65.22 kip.

Other 10 in tracks

Computed by the ColdCalc engine from the SSMA dimensions (design thickness, lip length and bend radius as in the SSMA conventions), E = 29,500 ksi, with rounded corners. Manufacturers' published values can differ slightly in rounding and corner modelling; ColdCalc's effective section modulus is within 3 % of the SSMA tables for all 775 studs and tracks compared. Results must be reviewed by a qualified engineer. Validation