Inputs

Where the load acts

Where loads act on the section unless a load has its own point: on the top flange over the web (deck bearing), at the shear center, or at the centroid.

A load that does not pass through the shear center twists the member. For a C-section the shear center is outside the web, so a load on the top flange twists it; for a Z it is at mid-web, so only the sloped component does. Choose 'Shear center' to ignore torsion from the loads. Any single load can act somewhere else: open its direction arrow, or pick it in the Model panel, and click the section where it acts (a hung load on the bottom flange, a bracket on a flange tip, a load through the shear center).