Calculation symbols
Moment at the strain limitMy3
Mp − (Mp − My)/9: the cap on the DSM local and distortional bending strengths, between first yield and the plastic moment.
- Specification
- AISI S100-24 Eq. F3.2-5
Mp − (Mp − My)/9: the cap on the DSM local and distortional bending strengths, between first yield and the plastic moment.