Bearing on the flange

Length over which the load bears on the flange. 0 = the load is not delivered through the flange (no web crippling check).

A post, a stud or a beam sitting on the flange pushes on the web from one side, so the web can cripple under it (§G5), and bending at the same point combines with it (§H3). Give the length of the bearing plate or member in contact. The load is taken as unfastened; it is two-flange loading when a support or another bearing load on the opposite flange is within 1.5h.

Typical values
1.5 to 6 in.
Specification
AISI S100-24 G5